Which of the following motors, the starter didn't use to limit high starting current.
DC Shunt Motor
DC Series Motor
Three-phase Induction Motor
Synchronous motor
Synchronous motor
A Synchronous Motor does not use a starter to limit high starting current, but rather to make the motor self-starting or to bring it up to synchronous speed. Because synchronous motors have zero starting torque, auxiliary starting arrangements (like damper windings or pony motors) are used for starting rather than for limiting armature current.
A Synchronous Motor does not use a starter to limit high starting current, but rather to make the motor self-starting or to bring it up to synchronous speed. Because synchronous motors have zero starting torque, auxiliary starting arrangements (like damper windings or pony motors) are used for starting rather than for limiting armature current.
IstartтАЛ=RaтАЛVтИТEbтАЛтАЛ тАФ Starting armature current in DC motors (where EbтАЛ=0 at start)
NsтАЛ=P120fтАЛ тАФ Synchronous speed of the motor
When a synchronous motor is connected to an AC supply, the stator magnetic field rotates at synchronous speed (NsтАЛ=P120fтАЛ). Due to the high inertia of the rotor, it cannot accelerate instantaneously to lock into step with the rotating stator field, producing zero average starting torque. Starters or damper windings are used to bring the rotor close to synchronous speed so magnetic locking can occur.
DC motors use 3-point or 4-point starters specifically to limit high starting current due to zero back EMF (EbтАЛ=0) at starting.
Three-phase induction motors use Star-Delta, Auto-transformer, or DOL starters to reduce high inrush current (5тИТ7 times full load current).
Synchronous motors are not inherently self-starting because the stator field rotates at synchronous speed while the rotor inertia prevents it from following instantaneous magnetic forces.
Starters for synchronous motors (e.g., damper windings, pony motors) are used to accelerate the motor to near-synchronous speed so magnetic locking can take place.
Option A (DC Shunt Motor): Uses starters (3-point or 4-point) to limit armature current at starting when EbтАЛ=0.
Option B (DC Series Motor): Uses a 2-point starter to limit starting current.
Option C (Three-phase Induction Motor): Uses Star-Delta or Autotransformer starters to limit high starting current.
D is correct тАФ Synchronous motors use starting methods (like damper windings or auxiliary motors) to provide starting torque and reach synchronous speed, not to limit high starting current.
Always distinguish between the purpose of a starter: for DC and Induction motors, it is primarily to limit high starting current; for Synchronous motors, it is primarily to produce starting torque.