Join 60,000+ competitive exam aspirants
Which of the following statements regarding corona are true?
It causes radio interference
It attenuates lightning surges
It amplifies switching surges
It causes power loss
It is more prevalent in the middle conductor of a transmission line employing a flat conductor configuration.
1, 3 and 5
2, 3 and 4
1, 2, 4 and 5
2, 3, 4 and 5
1, 2, 4 and 5
Corona is the partial discharge phenomenon occurring when the voltage gradient at the conductor surface exceeds the dielectric strength of the surrounding air. It leads to energy dissipation, electromagnetic interference, and chemical ozone formation, while simultaneously acting as a dampening mechanism for high-frequency transients.
Corona is the partial discharge phenomenon occurring when the voltage gradient at the conductor surface exceeds the dielectric strength of the surrounding air. It leads to energy dissipation, electromagnetic interference, and chemical ozone formation, while simultaneously acting as a dampening mechanism for high-frequency transients.
VcтАЛ=g0тАЛ╬┤m0тАЛrln(rDтАЛ) тАФ Disruptive critical voltage (rms)
PcтАЛтИЭ(f+25)DrтАЛтАЛ(VтИТVcтАЛ)2 тАФ Empirical power loss formula
When the electric field strength at the conductor surface exceeds the breakdown strength of air (approx. 30 kV/cm peak), air molecules ionize. This ionization creates a luminous glow and conductive path near the conductor, which increases the effective diameter of the conductor. Because this phenomenon is non-linear and consumes energy, it effectively attenuates the peak of incoming surge waves (lightning surges) while producing unwanted radio frequency noise and power losses (PcтАЛтИЭ(f+25)drтАЛтАЛ(VтИТVcтАЛ)2).
Corona produces ozone which is corrosive to conductor materials.
The middle conductor in a flat configuration has higher potential stress due to lack of symmetry, making it more prone to corona.
Corona provides an attenuation effect on traveling waves by absorbing surge energy.
Corona does NOT amplify switching surges; rather, it typically dissipates/limits their amplitude.
Reduces the steepness of incoming lightning surge wavefronts.
Acts as a natural surge protection mechanism by absorbing high-frequency components.
Causes significant I2R equivalent power loss.
Induces radio and television interference due to high-frequency harmonic generation.
Produces ozone, causing corrosion of overhead line conductors.
Used in the design of Bundle Conductors to increase effective radius and reduce corona.
Considered during the selection of ACSR conductor sizes to maintain surface gradients below critical limits.
Statement 3 is incorrect because corona acts as a damping element that limits, not amplifies, the peak magnitude of switching surges.
In a flat configuration, the middle conductor experiences a different electrostatic field compared to the outer conductors, leading to higher stress.
C is correct тАФ Corona causes power loss, radio interference, and lightning surge attenuation, and it is most pronounced on the middle conductor of a flat transmission configuration.
Always remember that corona is a self-limiting phenomenon; it dissipates energy, which is why it attenuates rather than amplifies voltage surges.