In EHV transmission lines, efficiency of transmission can be increased by decreasing the corona loss. This is achieved by
Increasing the distance between the line conductors
Using bundled conductors
Using thick conductors
Using thin conductors
Using bundled conductors
Corona loss in EHV lines is primarily caused by the ionization of air when the surface electric field intensity exceeds the dielectric strength of air. Bundled conductors increase the effective radius of the conductor, which reduces the maximum surface electric field intensity and consequently reduces corona loss.
Corona loss in EHV lines is primarily caused by the ionization of air when the surface electric field intensity exceeds the dielectric strength of air. Bundled conductors increase the effective radius of the conductor, which reduces the maximum surface electric field intensity and consequently reduces corona loss.
PcтАЛ=╬┤244тАЛ(f+25)DrтАЛтАЛ(VтИТVcтАЛ)2├Ч10тИТ5 тАФ Empirical formula for corona loss in kW per km per phase
E=rln(D/r)VтАЛ тАФ Electric field intensity at the surface of a conductor
The electric field intensity (E) at the surface of a conductor is inversely proportional to its effective radius (r). By using bundled conductors (multiple sub-conductors per phase), the overall geometric mean radius (GMR) increases. As the effective radius increases, the maximum electric field gradient at the surface of the bundle decreases below the disruptive critical voltage gradient, effectively suppressing corona discharge.
Corona loss is non-linear and increases significantly with the applied voltage.
Bundling conductors effectively increases the radius r, which reduces the surface stress E.
Corona discharge leads to power loss, radio interference, and audible noise.
The critical disruptive voltage VcтАЛ is directly proportional to the conductor radius r.
Reduces corona loss and audible noise
Increases the current-carrying capacity of the line
Reduces the line inductance, thereby increasing the surge impedance loading (SIL)
Higher mechanical complexity in tower design
Increased weight and cost due to additional hardware like spacers
Used in almost all EHV and UHV (above 220 kV) transmission lines
Helps in maintaining stability in long-distance power transmission
Corona is the breakdown of air which manifests as a glow, hissing noise, and ozone emission.
Option A (Increasing distance) actually increases the inductance of the line, which is generally undesirable for long-distance power transfer, though it slightly reduces the corona loss.
Option C (Thick conductors) is theoretically sound for reducing corona but is physically and economically impractical compared to bundling.
B is correct тАФ Using bundled conductors increases the effective radius of the conductor, thereby reducing the surface voltage gradient and the resulting corona loss.
Always remember that bundling increases the GMR, which lowers the shunt capacitance and reduces inductance, playing a dual role in both corona mitigation and improved voltage stability.