Join 60,000+ competitive exam aspirants
A cantilever beam of length 2 m is subjected to a point load of 3 kN at a distance of 2 m and is subjected to a UDL of 3 kN/m for a total distance of 1.5 m from the fixed end. Calculate the shear force and bending moment at the fixed end.
−5.75 kN, −5.545 kN-m
−10 kN, 15.254 kN-m
−12.5 kN, −8.547 kN-m
−7.5 kN, −9.375 kN-m
−7.5 kN, −9.375 kN-m
At the fixed end of a cantilever beam, the shear force is the algebraic sum of all vertical loads, and the bending moment is the algebraic sum of the moments of all loads about the fixed support. For this beam, the total vertical reaction is the sum of the point load and the resultant of the UDL, while the total bending moment is the sum of moments produced by these loads acting at their respective distances.
IS 456:2000 Cl. 22.2
At the fixed end of a cantilever beam, the shear force is the algebraic sum of all vertical loads, and the bending moment is the algebraic sum of the moments of all loads about the fixed support. For this beam, the total vertical reaction is the sum of the point load and the resultant of the UDL, while the total bending moment is the sum of moments produced by these loads acting at their respective distances.
Vfixed=−(∑P+w×Ludl) — Total shear force at fixed end
Mfixed=−(∑P⋅xi+w×Ludl×2Ludl) — Total bending moment at fixed end
The principle of static equilibrium is applied to calculate the reactions. The shear force at the support is V=∑Fy, and the bending moment is M=∑Mfixed. Since the cantilever beam is fixed at one end, all external downward loads create a negative bending moment (hogging) and negative shear force based on standard sign conventions.
Shear force calculation: V=−(3 kN+3 kN/m×1.5 m)=−(3+4.5)=−7.5 kN.
Bending moment calculation: M=−(3 kN×2 m+3 kN/m×1.5 m×21.5 m)=−(6+3.375)=−9.375 kN-m.
Simple direct summation for cantilever systems
Accurate prediction of support failure modes
Does not account for beam deflection directly
Sensitive to length parameters
Structural design of building overhangs
Analysis of retaining walls
The point load is at x=2 m, while the UDL spans from 0 to 1.5 m, so the centroid of the UDL is at 0.75 m from the support.
Option D is calculated as V=−7.5 kN and M=−9.375 kN-m correctly.
D is correct — The total shear force is −7.5 kN and the total bending moment at the fixed support is −9.375 kN-m.
For cantilever beams, always check if the UDL covers the entire span or only a portion, as the lever arm for the UDL is measured to its centroid.