A catchment area of 10 km┬▓ has recorded a rainfall of 25 mm/h. Assuming a runoff co- efficient of 0.3, the peak discharge from the catchment using the rational method is ________.
18.36 cumec
20.83 cumec
24.6 cumec
26.56 cumec
20.83 cumec
The Rational Method relates peak runoff to rainfall intensity using the empirical formula Q=3.61тАЛтЛЕCтЛЕiтЛЕA. Given a catchment area A=10┬аkm2, rainfall intensity i=25┬аmm/h, and runoff coefficient C=0.3, the peak discharge is calculated as Q=3.60.3├Ч25├Ч10тАЛ=20.83┬аm3/s.
IRC:SP:13 (Guidelines for the Design of Small Bridges and Culverts)
The Rational Method relates peak runoff to rainfall intensity using the empirical formula Q=3.61тАЛтЛЕCтЛЕiтЛЕA. Given a catchment area A=10┬аkm2, rainfall intensity i=25┬аmm/h, and runoff coefficient C=0.3, the peak discharge is calculated as Q=3.60.3├Ч25├Ч10тАЛ=20.83┬аm3/s.
Q=3.61тАЛтЛЕCтЛЕiтЛЕA тАФ The Rational Method formula where Q is peak discharge (m3/s), C is runoff coefficient, i is intensity (mm/h), and A is area (km2).
The Rational Method assumes that rainfall intensity is uniform over the entire catchment area and that the duration of rainfall equals the time of concentration. It calculates the peak discharge by considering the proportion of rainfall that results in surface runoff, expressed by the runoff coefficient.
The constant 1/3.6 arises from unit conversion: 3600┬аs1┬аkm2├Ч1┬аmm/hтАЛ=3600┬аs106┬аm2├Ч10тИТ3┬аmтАЛ=3.61тАЛ┬аm3/s.
The Rational Method is most reliable for small catchments where the time of concentration is less than 50 hectares.
The runoff coefficient C depends on land use, soil permeability, and slope.
Simple and easy to calculate for small basins.
Widely used for urban drainage design.
Does not account for the temporal distribution of rainfall.
Not suitable for large catchment areas exceeding 50 sq. km.
Design of storm sewers.
Small bridge and culvert hydraulic design.
Calculation: Q=3.60.3├Ч25├Ч10тАЛ=3.675тАЛ=20.833┬аcumec.
Options were tested against the formula Q=3.61тАЛCIA. Other options represent calculation errors or incorrect unit conversions.
B is correct тАФ Using the Rational Method formula Q=3.61тАЛCIA, the substitution yields 20.83┬аcumec.
Always verify units before plugging values into the Rational Method; ensure area is in km2 and intensity is in mm/h to use the 1/3.6 constant.