Join 60,000+ competitive exam aspirants
A lightning arrester provides
Low impedance path
High impedance path
Low resistance path
High resistance path between line and earth during operation
Low impedance path
A lightning arrester is a protective device used in electrical power systems to protect insulation and conductors from the damaging effects of lightning surges or switching surges. It operates by providing a low impedance path to the ground for the surge current, thereby diverting it away from the protected equipment.
A lightning arrester is a protective device used in electrical power systems to protect insulation and conductors from the damaging effects of lightning surges or switching surges. It operates by providing a low impedance path to the ground for the surge current, thereby diverting it away from the protected equipment.
VdischargeтАЛ=VsparkoverтАЛ+IsurgeтАЛтЛЕZarresterтАЛ тАФ Represents the residual voltage across the arrester during operation, where ZarresterтАЛ must be minimal.
Under normal operating conditions, the arrester acts as an open circuit (high impedance) between the line and earth. When an overvoltage (surge) exceeds the breakdown voltage of the arrester, it instantly transitions to a conducting state, offering a low impedance path to ground. This limits the voltage across the equipment to a safe value known as the discharge voltage.
Installed in parallel with the equipment to be protected.
Must have a high spark-over voltage to avoid operation under normal system voltage.
Non-linear resistors (like Silicon Carbide or Metal Oxide Varistors) are typically used.
Total surge energy must be dissipated without damage to the arrester.
Prevents catastrophic failure of transformers and insulators.
Reduces the magnitude of transient overvoltages.
Automatically resets after the surge has passed.
Can fail if subjected to thermal runaway or multiple high-energy surges.
Requires periodic inspection and maintenance.
Power Transformers
Transmission Lines
Switchgear Busbars
The most common modern type is the Metal Oxide Arrester (MOA), which lacks a spark gap.
Option B and D are incorrect because a high impedance/resistance path would block the surge, causing the voltage across the protected equipment to rise significantly, potentially leading to insulation failure.
A is correct тАФ A lightning arrester diverts surge currents to the ground by creating a low impedance path when the voltage exceeds the protective level.
Always remember that protective devices like arresters work in parallel, while fuses/breakers work in series; arresters must have low impedance to ground to function.