The lightning arrester is conducted
in series with the line
between line and earth
to a pole near the line
to circuit breaker
between line and earth
A lightning arrester (surge arrester) is a protective device used in electrical power systems to protect equipment from high-voltage surges caused by lightning or switching operations. It is connected in parallel (shunt) between the phase conductor and the earth, allowing it to divert excess voltage transients to the ground without interrupting the continuity of power flow.
A lightning arrester (surge arrester) is a protective device used in electrical power systems to protect equipment from high-voltage surges caused by lightning or switching operations. It is connected in parallel (shunt) between the phase conductor and the earth, allowing it to divert excess voltage transients to the ground without interrupting the continuity of power flow.
IdischargeтАЛ=ZsurgeтАЛVsurgeтАЛтИТVresidualтАЛтАЛ тАФ Represents the discharge current flowing through the arrester during a surge event.
Under normal operating conditions, the arrester acts as an insulator and offers a very high impedance to the line voltage. When a high-voltage surge occurs, the arrester's impedance drops instantly to a low value, providing a low-resistance path to the ground for the surge current. Once the voltage returns to normal, the arrester regains its high-impedance state to prevent the flow of power-frequency follow-through current.
Lightning arresters are shunt-connected protective devices.
They are designed to bypass surge currents to the ground.
They maintain a specific residual voltage level known as the discharge voltage.
They must have a high degree of reliability to prevent power system shutdown during discharge.
Protects expensive assets like transformers and switchgear.
Prevents insulation failure due to voltage spikes.
High-speed response to transient voltages.
Requires proper maintenance to ensure effectiveness.
Can fail if surge energy exceeds its thermal capacity.
High-voltage substations
Distribution transformer protection
Overhead power lines
The lightning arrester must be able to withstand the system's normal operating voltage while being ready to clamp surges.
Option A is incorrect because a series connection would disconnect the line during a surge. Options C and D are structurally inappropriate for effective surge diversion.
B is correct тАФ Lightning arresters are installed in parallel between the line and earth to provide a low-impedance path to the ground during voltage surges.
Always remember: Protective devices that divert current to ground (arresters) are always connected in parallel, while devices meant to interrupt or control current flow (fuses, circuit breakers) are connected in series.