Air preheater in a steam power plant
Recovers the heat from the flue gases leaving the economizer
Improves combustion rate
Raises the temperature of the furnace gases
All of above
Raises the temperature of the furnace gases
An air preheater is a heat-recovery device placed in the flue gas path of a steam power plant to extract residual heat from gases exiting the economizer. By transferring this heat to the incoming combustion air, it increases the thermal efficiency of the plant while simultaneously improving the fuel combustion process.
An air preheater is a heat-recovery device placed in the flue gas path of a steam power plant to extract residual heat from gases exiting the economizer. By transferring this heat to the incoming combustion air, it increases the thermal efficiency of the plant while simultaneously improving the fuel combustion process.
╬╖boilerтАЛ=mfтАЛтЛЕCVmsтАЛ(hsтАЛтИТhwтАЛ)тАЛ├Ч100 тАФ Represents the boiler efficiency which increases as input air temperature rises
Q=m╦ЩairтАЛCp,airтАЛ(ToutтАЛтИТTinтАЛ) тАФ Represents the heat gain by combustion air
The device utilizes the flue gas, which still contains significant thermal energy, to pre-heat the primary and secondary combustion air. This elevated inlet air temperature facilitates faster fuel ignition, promotes more complete combustion with less excess air, and protects the furnace lining from large temperature gradients.
Increases steam generator efficiency by roughly 1% for every 20┬░C rise in air temperature.
Reduces the required amount of excess air, leading to lower nitrogen oxide emissions.
Constructed usually as tubular or regenerative (Ljungstrom) type heat exchangers.
Located after the economizer to extract heat before gases pass through the dust collector to the chimney.
Improved combustion efficiency.
Reduced fuel consumption.
Better flame stability in the furnace.
Increases fan power consumption due to pressure drop.
Risk of low-temperature corrosion if gas temperature falls below the dew point of sulfur compounds.
Utility thermal power plants.
Industrial steam boilers.
Waste heat recovery units.
The flue gases at this stage are typically at 300-400┬░C before entering the preheater.
Option C is correct because the heat added to the combustion air results in a higher furnace temperature upon fuel ignition, facilitating better radiative heat transfer.
D is correct тАФ The air preheater functions as a secondary heat recovery stage that improves overall combustion efficiency and furnace performance by utilizing waste energy from flue gases.
Always remember the order of heat recovery components: Superheater тЖТ Reheater тЖТ Economizer тЖТ Air Preheater. This is a common sequence tested in power generation exams.