Join 60,000+ competitive exam aspirants
Armature reaction effect is more in which of the following speed control methods?
field weakening method
armature resistance control
same in both methods
none of the above
field weakening method
Field weakening is a method of speed control in DC motors where the flux per pole is intentionally reduced. Because armature reaction is proportional to the armature current (IaтАЛ) and inversely dependent on the main field flux (or rather, its relative strength against the weakening flux), the distorting and demagnetizing effects of armature reaction become significantly more pronounced as the main flux is reduced.
Field weakening is a method of speed control in DC motors where the flux per pole is intentionally reduced. Because armature reaction is proportional to the armature current (IaтАЛ) and inversely dependent on the main field flux (or rather, its relative strength against the weakening flux), the distorting and demagnetizing effects of armature reaction become significantly more pronounced as the main flux is reduced.
N=KnтАЛ╬жVтИТIaтАЛRaтАЛтАЛ тАФ DCMotor speed equation
ATarтАЛтИЭIaтАЛ тАФ Armature reaction ampere-turns
In a DC motor, speed NтИЭ╬жEbтАЛтАЛ. By increasing the field resistance, the field current and consequently the main flux (╬ж) are decreased, forcing the motor speed to increase. As ╬ж decreases, the ratio of the cross-magnetizing armature mmf to the main field mmf increases, leading to higher distortion of the air-gap flux density distribution and potential commutation issues.
Field weakening is used for speeds above the rated speed.
Reducing main flux weakens the 'magnetic stiffness' of the machine.
High armature reaction leads to sparking at brushes due to flux distortion.
Armature resistance control is used for speeds below rated speed.
Allows speed control above the base rated speed.
Efficiency is not significantly sacrificed compared to resistance control.
Increased armature reaction effects.
Potential for commutator sparking.
Risk of motor running at dangerously high speeds if field circuit opens.
Rolling mills
Electric locomotives
Machine tool drives requiring constant power output
| Feature | Field Weakening | Armature Resistance |
|---|---|---|
Speed Range | Above rated speed | Below rated speed |
Armature Reaction | High impact | Low impact |
In armature resistance control, the main field flux remains constant, meaning the demagnetizing effect of armature reaction remains relatively stable.
Field weakening is a constant power method, whereas armature resistance control is a constant torque method.
A is correct тАФ The reduction of the main field flux in the field weakening method increases the relative impact of armature reaction, often leading to commutation difficulties.
Always remember: Field control affects the magnetic circuit (╬ж)while armature control affects the electrical circuit (IaтАЛ RaтАЛ). If the main flux is low, the machine is more susceptible to external magnetic interference.