As per IS 456: 2000, the design strength of a short axially loaded compression member is expressed as _______. Where, f y =characteristic strength of the compression reinforcement, A sc =area of longitudinal reinforcement for columns, f ck =characteristic compressive strensth of the concrete, A c =Area of concrete.





According to IS 456:2000, the design axial load capacity (PuтАЛ) of a short reinforced concrete column is calculated by summing the contributions of the concrete and the longitudinal steel reinforcement. The concrete area (AcтАЛ) is considered to contribute 0.4fckтАЛ and the steel area (AscтАЛ) is considered to contribute 0.67fyтАЛ, accounting for safety factors and expected strain profiles in the members.
IS 456:2000 Clause 39.3
According to IS 456:2000, the design axial load capacity (PuтАЛ) of a short reinforced concrete column is calculated by summing the contributions of the concrete and the longitudinal steel reinforcement. The concrete area (AcтАЛ) is considered to contribute 0.4fckтАЛ and the steel area (AscтАЛ) is considered to contribute 0.67fyтАЛ, accounting for safety factors and expected strain profiles in the members.
PuтАЛ=0.4fckтАЛAcтАЛ+0.67fyтАЛAscтАЛ тАФ Represents the ultimate axial load capacity of a short compression member
The structural strength is derived from the superimposition of the axial load-carrying capacities of the concrete and the steel reinforcement. The coefficients 0.4 for concrete and 0.67 for steel are empirically derived factors in the limit state design method to ensure safety against crushing and buckling in short columns.
This formula is applicable specifically to short axially loaded columns.
The area of concrete AcтАЛ is equal to the gross area AgтАЛ minus the area of steel AscтАЛ.
It assumes the column is short, meaning slenderness effects are ignored.
The factor 0.67 comes from 1.3150.87fyтАЛтАЛтЙИ0.67fyтАЛ after considering design stress in reinforcement.
Simple analytical approach for column design.
Accounts for both material strengths effectively.
Does not account for slenderness effects.
Requires additional analysis for moments due to eccentricity.
Design of short reinforced concrete columns in multi-story buildings.
Verification of axial capacity for structural elements under pure compression.
IS 456:2000 mandates that for all columns, the design should also satisfy requirements for minimum eccentricity.
The other options provided use incorrect coefficients or reversed variables that do not align with the standard design equation.
C is correct тАФ The design axial load capacity of a short reinforced concrete column is determined by the formula 0.4fckтАЛAcтАЛ+0.67fyтАЛAscтАЛ.
Always remember the coefficient pair (0.4,0.67) for axial column capacity, as it is a frequent point of confusion with beam flexure formulas (0.36fckтАЛbxuтАЛ,0.87fyтАЛAstтАЛ).