Join 60,000+ competitive exam aspirants
Identify the INCORRECT statement with respect to specifications on the partial safety factors for material strength, and are used in limit state design of RC structures
A partial safety factor 1.5 is used for concrete under ultimate limit state
A higher partial safety factor has been assigned to concrete compared with reinforcing steel under the ultimate limit state.
A partial safety factor 1.0 is used for steel under serviceability limit state
A partial safety factor 1 is used for concrete under serviceability limit state
A partial safety factor 1.0 is used for steel under serviceability limit state
In the Limit State Design (LSD) method, partial safety factors are applied to material strengths to account for uncertainties. For the Serviceability Limit State (SLS), the partial safety factor for both concrete and steel is taken as 1.0, whereas for the Ultimate Limit State (ULS), they are 1.5 and 1.15 respectively.
IS 456:2000, Table 18, Clause 36.4.2
In the Limit State Design (LSD) method, partial safety factors are applied to material strengths to account for uncertainties. For the Serviceability Limit State (SLS), the partial safety factor for both concrete and steel is taken as 1.0, whereas for the Ultimate Limit State (ULS), they are 1.5 and 1.15 respectively.
fdтАЛ=gammamтАЛfkтАЛтАЛ тАФ Design strength calculation where fkтАЛ is characteristic strength and gammamтАЛ is partial safety factor
The partial safety factor (gammamтАЛ) is used to reduce the characteristic strength (fkтАЛ) to design strength (fdтАЛ=gammamтАЛfkтАЛтАЛ). In serviceability, we use expected actual behavior, hence gammamтАЛ=1.0. In ultimate conditions, we incorporate a margin of safety to prevent collapse, necessitating higher factors for concrete due to higher material variability compared to factory-produced steel.
Partial safety factor for concrete at ULS is 1.5.
Partial safety factor for reinforcing steel at ULS is 1.15.
Partial safety factor for both materials at SLS is 1.0.
Concrete has a higher partial safety factor than steel at ULS due to greater quality control variability in site-cast concrete.
Provides a consistent level of safety across structural elements.
Accounts for the statistical variation in material properties.
Requires complex calculations compared to Working Stress Method.
Dependent on accurate assessment of characteristic loads and strengths.
Design of reinforced concrete beams, columns, and slabs.
Assessment of structural safety in existing RC structures.
Option C is incorrect because the factor for steel at SLS is 1.0, not 1.15. The value 1.15 is specific to steel at the ULS.
Concrete's higher factor (1.5) compared to steel (1.15) at ULS reflects higher uncertainty in concrete quality during construction.
C is correct тАФ The partial safety factor for steel under serviceability limit state is 1.0, not 1.15.
Remember that for SLS, the partial safety factor is always 1.0 for all materials, whereas ULS uses 1.5 for concrete and 1.15 for steel.