As per IS 456:2000, the minimum cross sectional area of longitudinal reinforcement(irrespective of load requirement) in a RCC column of size 150x300 mm shall NOT be less than_____. Consider the limit state method of design.
440 mm┬▓
360 mm┬▓
240 mm┬▓
780 mm┬▓
360 mm┬▓
According to IS 456:2000, the minimum percentage of longitudinal reinforcement in a column is 0.8% of the gross cross-sectional area. For a column of size 150┬аmm├Ч300┬аmm, the gross area is 45,000┬аmm2.
IS 456:2000 Cl. 26.5.3.1
According to IS 456:2000, the minimum percentage of longitudinal reinforcement in a column is 0.8% of the gross cross-sectional area. For a column of size 150┬аmm├Ч300┬аmm, the gross area is 45,000┬аmm2.
Asc,minтАЛ=1000.8тАЛ├ЧAgтАЛ тАФ where AgтАЛ is the gross cross-sectional area of the column.
The minimum reinforcement requirement is mandated to account for unexpected bending moments, shrinkage, and creep in concrete. It ensures that the column maintains structural integrity even under light loading conditions and provides ductility to the compression member.
The minimum area of reinforcement is 0.8% of the gross area.
The maximum area of reinforcement is 4% of the gross area if bars can be lapped.
For this column, 0.008├Ч150├Ч300=360┬аmm2.
Columns must have at least 4 longitudinal bars in rectangular sections.
Provides resistance to accidental eccentric loading
Mitigates long-term deformation due to creep and shrinkage
High reinforcement percentages increase congestion, making concrete placement difficult
Excessive steel can lead to brittle failure if not properly confined
RCC building columns
Compression members in framed structures
The calculation is AscтАЛ=0.008├Ч45000=360┬аmm2.
Option A is incorrect as it overestimates the requirement.
Option C is incorrect as it is below the code minimum.
Option D is also incorrect and significantly higher than the minimum.
B is correct тАФ The minimum longitudinal reinforcement is calculated as 0.8% of the gross cross-sectional area, which equals 360┬аmm2.
Remember that the minimum 0.8% is based on the gross concrete area AgтАЛ, not the net area AcтАЛ (which is AgтАЛтИТAscтАЛ).