Join 60,000+ competitive exam aspirants
Bundle conductor in EHV transmission line results to
Reduce inductance
Increase capacitance
Increase inductance
Increase resistance
Reduce inductance
Bundle conductors consist of two or more stranded conductors connected in parallel per phase, which increases the Geometric Mean Radius (GMR) of the phase. Since inductance L=2├Ч10тИТ7ln(GMRLтАЛGMDтАЛ), increasing the GMRLтАЛ effectively reduces the line inductance.
Bundle conductors consist of two or more stranded conductors connected in parallel per phase, which increases the Geometric Mean Radius (GMR) of the phase. Since inductance L=2├Ч10тИТ7ln(GMRLтАЛGMDтАЛ), increasing the GMRLтАЛ effectively reduces the line inductance.
L=2├Ч10тИТ7ln(GMRLтАЛGMDтАЛ) тАФ Inductance per meter length
C=ln(GMRCтАЛGMDтАЛ)2╧А╧╡0тАЛтАЛ тАФ Capacitance per meter length
In an EHV transmission line, increasing the number of conductors in a bundle increases the self-Geometric Mean Distance (GMR). Because the inductance of a transmission line is inversely proportional to the logarithm of the GMR, increasing the effective radius of the conductor bundle significantly lowers the inductive reactance of the line, improving stability and increasing the surge impedance loading (SIL) capacity.
Bundle conductors increase the GMR, leading to reduced inductance.
Bundle conductors increase the effective radius, leading to increased capacitance.
The primary purpose of bundling is to reduce the voltage gradient on the conductor surface, thereby minimizing corona loss and radio interference.
Bundling increases the Surge Impedance Loading (SIL) of the line.
Reduced corona loss and radio interference
Increased power transmission capacity (SIL)
Reduced inductive reactance
Better voltage regulation
Higher weight per unit length
Increased wind and ice loading on towers
Increased cost due to more conductor material and complex spacers
400 kV and 765 kV transmission systems
HVDC transmission lines
Option B is also technically true as bundling increases capacitance due to higher effective radius; however, the primary electrical design objective for EHV is often the reduction of inductance and corona. In competitive exams, 'reduce inductance' is the standard primary effect cited.
For n conductors in a bundle with radius r and spacing d, the GMRLтАЛ is approximately (n├ЧreqтАЛ├ЧdnтИТ1)1/n.
A is correct тАФ Bundle conductors increase the Geometric Mean Radius (GMR), which mathematically results in a reduction of the transmission line's inductive reactance.
Always remember that while bundling increases capacitance, its most significant impact on steady-state stability is the reduction of inductance, which increases the maximum power transfer capability of the line.