Coefficient of discharge (Cd) of a flow-measuring device is defined as the _________.
product of actual discharge and theoretical discharge
product of cross-sectional area and velocity
ratio of actual discharge to theoretical discharge
ratio of theoretical discharge to actual discharge
ratio of actual discharge to theoretical discharge
The coefficient of discharge, denoted by CdтАЛ, is a non-dimensional parameter used to quantify the efficiency of a flow-measuring device. It is defined as the ratio of the actual discharge (QactтАЛ) passing through the device to the theoretical discharge (QthтАЛ) calculated using the energy equation (Bernoulli's theorem) under ideal, frictionless conditions.
ISO 5167
The coefficient of discharge, denoted by CdтАЛ, is a non-dimensional parameter used to quantify the efficiency of a flow-measuring device. It is defined as the ratio of the actual discharge (QactтАЛ) passing through the device to the theoretical discharge (QthтАЛ) calculated using the energy equation (Bernoulli's theorem) under ideal, frictionless conditions.
CdтАЛ=QthтАЛQactтАЛтАЛ тАФ Definition of coefficient of discharge
QthтАЛ=A1тАЛA2тАЛA12тАЛтИТA22тАЛ2gHтАЛтАЛ тАФ Theoretical discharge for a venturimeter
In an ideal fluid flow, energy is conserved without loss. However, real fluids possess viscosity, which leads to frictional losses, flow separation, and the formation of a vena contracta. CdтАЛ accounts for these real-world effects, adjusting the theoretical calculation to match the observed actual flow rate.
It is a dimensionless constant for a specific geometry.
Actual flow is always less than theoretical flow, so CdтАЛ<1.
It compensates for energy losses and the contraction of the fluid stream.
For well-designed Venturimeters, CdтАЛ typically ranges from 0.95 to 0.99.
Standardizes comparison between different flow meters.
Essential for calibrating flow-measuring devices.
Value depends on Reynolds number, making it slightly variable at low flows.
Requires experimental calibration.
Venturimeter performance analysis.
Orifice meter flow calibration.
Flow nozzle efficiency evaluation.
The value of CdтАЛ depends on the type of device; for example, an orifice meter has a significantly lower CdтАЛ (тЙИ0.62тИТ0.65) than a venturimeter due to greater flow separation.
Option A is incorrect because multiplication would result in a dimensional error. Option D is the reciprocal, known as the inverse of the discharge coefficient.
C is correct тАФ The coefficient of discharge is defined as the ratio of actual discharge to theoretical discharge.
Always remember that CdтАЛ represents the ratio of actual over theoretical; mnemonic 'A over T' (Actual over Theoretical) helps avoid confusion with the reciprocal.