Deaerative heating is done to
Heat the steam
Heat the feed water
Remove dissolved gases in water
Remove dissolved solid impurities in water
Remove dissolved gases in water
Deaerative heating is a crucial process in thermal power plants used to remove dissolved corrosive gases like oxygen (O2тАЛ) and carbon dioxide (CO2тАЛ) from the feed water. By heating the water to its saturation temperature, the solubility of these gases is drastically reduced, allowing them to be vented out, thereby preventing boiler corrosion and pitting.
Deaerative heating is a crucial process in thermal power plants used to remove dissolved corrosive gases like oxygen (O2тАЛ) and carbon dioxide (CO2тАЛ) from the feed water. By heating the water to its saturation temperature, the solubility of these gases is drastically reduced, allowing them to be vented out, thereby preventing boiler corrosion and pitting.
C=kтЛЕPgтАЛ тАФ Henry's Law: solubility (C) of gas is proportional to partial pressure (PgтАЛ)
The process operates on Henry's Law, which states that the solubility of a gas in a liquid is proportional to its partial pressure. By spraying feed water into a steam-filled chamber (deaerator), the water is heated to saturation, lowering the partial pressure of dissolved gases and facilitating their liberation from the liquid phase. The stripped gases are then removed through a vent system.
Dissolved oxygen causes severe pitting and oxidation of boiler tubes.
The deaerator also acts as an open feed water heater.
It improves the thermal efficiency of the Rankine cycle by preheating the feed water.
Proper deaeration is essential for high-pressure boiler longevity.
Prevents internal corrosion of steam generating equipment.
Improves thermal efficiency by reducing heat loss.
Eliminates the need for excessive chemical oxygen scavengers.
Requires high initial capital cost for deaerator installation.
Regular maintenance of vent valves and spray nozzles is required.
Thermal Power Plants
Industrial Steam Boilers
Marine Propulsion Plants
Oxygen levels in boiler feed water should ideally be kept below 0.007 mg/L for high-pressure systems.
Option A is incorrect because heating steam is the source of heat, not the objective of the deaerator.
Option D is incorrect because solids are removed via water treatment processes like demineralization or reverse osmosis, not deaeration.
C is correct тАФ Deaerative heating uses steam to heat feed water, thereby reducing the solubility of dissolved gases like O2тАЛ and CO2тАЛ so they can be removed.
Always remember that in power systems, deaeration is a physical process, while demineralization is a chemical/mechanical process for removing dissolved solids.