For a dc machine shunt resistance and armature resistance values are
high and high
high and low
low and low
low and high
high and low
In a DC machine, the armature winding carries the main load current and must have a very low resistance to minimize I2R power losses and voltage drop. The shunt field winding consists of many turns of fine wire to create a high-resistance path, ensuring that only a small fraction of the total current is drawn from the supply to establish the necessary magnetic flux.
In a DC machine, the armature winding carries the main load current and must have a very low resistance to minimize I2R power losses and voltage drop. The shunt field winding consists of many turns of fine wire to create a high-resistance path, ensuring that only a small fraction of the total current is drawn from the supply to establish the necessary magnetic flux.
PlossтАЛ=Ia2тАЛRaтАЛ тАФ Power loss in the armature, minimized by low RaтАЛ
IshтАЛ=RshтАЛVтАЛ тАФ Current in shunt winding, limited by high RshтАЛ
The armature resistance (RaтАЛ) is kept low (typically <1┬а╬й) to maintain high efficiency and prevent excessive heat dissipation during load operation. Conversely, the shunt field winding is designed with high resistance (RshтАЛ) to limit current drawn (IshтАЛ=RshтАЛVтАЛ), allowing the shunt coil to be energized across the terminal voltage without requiring excessive power consumption.
Armature resistance must be low to avoid thermal runaway and poor efficiency.
Shunt winding uses many turns of thin wire, inherently leading to high resistance.
DC shunt motors/generators rely on this high-resistance field path to maintain constant flux.
Excessive armature resistance causes large internal voltage drops: VtтАЛ=EgтАЛтИТIaтАЛRaтАЛ.
High efficiency in armature circuit
Minimal power wastage in shunt field excitation
Low armature resistance can lead to high starting current
High shunt resistance limits the maximum field current control range
DC Shunt Generators
Constant speed DC Shunt Motors
Typical RaтАЛ values are often in the range of 0.05┬а╬й to 0.5┬а╬й.
Typical RshтАЛ values range from 50┬а╬й to several hundred ╬й depending on the machine rating.
Option A (high/high) would lead to massive power loss and poor torque; Option C (low/low) would cause short-circuit current in the field path; Option D (low/high) is the inverse of the required configuration.
B is correct тАФ Shunt resistance is high to limit field current, and armature resistance is low to minimize power loss.
Always remember: 'Armature = Power Transfer (Low R)', 'Field/Shunt = Control/Excitation (High R)' for all DC machine types.