Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

0.2 pu рдХреЗ рдкреНрд░рддрд┐рдШрд╛рдд (reactance) рд╡рд╛рд▓реЗ рдПрдХ рдлреАрдбрд░ рдХрд╛ рд╕реЗрдВрдбрд┐рдВрдЧ-рдПрдВрдб рд╡реЛрд▓реНрдЯреЗрдЬ 1.2 pu рд╣реИред рдпрджрд┐ рдлреАрдбрд░ рдХреЗ рд░рд┐рд╕реАрд╡рд┐рдВрдЧ-рдПрдВрдб рдкрд░ рдЖрдкреВрд░реНрддрд┐ рдХреА рдЧрдИ рдкреНрд░рддрд┐рдХреНрд░рд┐рдпрд╛рд╢реАрд▓ рд╢рдХреНрддрд┐ (reactive power) 0.3 pu рд╣реИ, рддреЛ рдлреАрдбрд░ рдореЗрдВ рдЕрдиреБрдорд╛рдирд┐рдд рд╡реЛрд▓реНрдЯреЗрдЬ рдбреНрд░реЙрдк рд╣реЛрдЧрд╛

A

042 pu

B

052 pu

C

060 pu

D

070 pu

Correct Answer

тЪЩя╕П TE тАв Technical рд╕рдиреНрдирд┐рдХрдЯрди рд╕реВрддреНрд░ElectricalPower System
B

052 pu

Quick Summary:

B рд╕рд╣реА рд╣реИ рдХреНрдпреЛрдВрдХрд┐ рдЕрдиреБрдорд╛рдирд┐рдд рдЧрдгрдирд╛ 0.05┬аpu0.05\text{ pu}0.05┬аpu рдкреНрд░рд╛рдкреНрдд рд╣реЛрддреА рд╣реИ, рдЬреЛ рдХрд┐ рджрд┐рдП рдЧрдП рд╡рд┐рдХрд▓реНрдк 0.052┬аpu0.052\text{ pu}0.052┬аpu рдХреЗ рдЕрдиреБрд░реВрдк рд╣реИред

ЁЯУРMAMath Solutionрд╕рдиреНрдирд┐рдХрдЯрди рд╕реВрддреНрд░
ЁЯУЛ Given

рдлреАрдбрд░ рдкреНрд░рддрд┐рдШрд╛рдд X = 0.2 pu, рд╕реЗрдВрдбрд┐рдВрдЧ-рдПрдВрдб рд╡реЛрд▓реНрдЯреЗрдЬ Vs = 1.2 pu, рд░рд┐рд╕реАрд╡рд┐рдВрдЧ-рдПрдВрдб рдкрд░ рдкреНрд░рддрд┐рдХреНрд░рд┐рдпрд╛рд╢реАрд▓ рд╢рдХреНрддрд┐ Q = 0.3 pu

ЁЯФв Formula Used

╬ФVтЙИQ├ЧXVs\Delta V \approx \frac{Q \times X}{V_s}╬ФVтЙИVsтАЛQ├ЧXтАЛ

ЁЯФв Step-by-Step Solution
1

рд╕рдиреНрдирд┐рдХрдЯрди рд╕реВрддреНрд░ рдХреА рдкрд╣рдЪрд╛рди рдХрд░реЗрдВ

рдЫреЛрдЯреА рдЯреНрд░рд╛рдВрд╕рдорд┐рд╢рди рд▓рд╛рдЗрдиреЛрдВ рдпрд╛ рдлреАрдбрд░реЛрдВ рдХреЗ рд▓рд┐рдП рдЬрд╣рд╛рдБ рдкреНрд░рддрд┐рд░реЛрдз рдирдЧрдгреНрдп рд╣реЛрддрд╛ рд╣реИ, рдЕрдиреБрдорд╛рдирд┐рдд рд╡реЛрд▓реНрдЯреЗрдЬ рдбреНрд░реЙрдк ╬ФV\Delta V╬ФV рдХрд╛ рд╕реВрддреНрд░ рдкреНрд░рддрд┐рдХреНрд░рд┐рдпрд╛рд╢реАрд▓ рд╢рдХреНрддрд┐ QQQ, рдкреНрд░рддрд┐рдШрд╛рдд XXX, рдФрд░ рд╕реЗрдВрдбрд┐рдВрдЧ-рдПрдВрдб рд╡реЛрд▓реНрдЯреЗрдЬ VsV_sVsтАЛ рдХреЗ рдЙрдкрдпреЛрдЧ рд╕реЗ рджрд┐рдпрд╛ рдЬрд╛рддрд╛ рд╣реИред

╬ФVтЙИQтЛЕXVs\Delta V \approx \frac{Q \cdot X}{V_s}╬ФVтЙИVsтАЛQтЛЕXтАЛ

2

рджрд┐рдП рдЧрдП рдорд╛рдиреЛрдВ рдХреЛ рдкреНрд░рддрд┐рд╕реНрдерд╛рдкрд┐рдд рдХрд░реЗрдВ

рджрд┐рдпрд╛ рдЧрдпрд╛ рд╣реИ Q=0.3┬аpuQ = 0.3\text{ pu}Q=0.3┬аpu, X=0.2┬аpuX = 0.2\text{ pu}X=0.2┬аpu, рдФрд░ Vs=1.2┬аpuV_s = 1.2\text{ pu}VsтАЛ=1.2┬аpuред рдЗрдиреНрд╣реЗрдВ рд╕реВрддреНрд░ рдореЗрдВ рд░рдЦрдиреЗ рдкрд░:

╬ФVтЙИ0.3├Ч0.21.2\Delta V \approx \frac{0.3 \times 0.2}{1.2}╬ФVтЙИ1.20.3├Ч0.2тАЛ

3

рдЧрдгрдирд╛ рдХрд░реЗрдВ

рдЕрдВрд╢ 0.3├Ч0.2=0.060.3 \times 0.2 = 0.060.3├Ч0.2=0.06 рдХреА рдЧрдгрдирд╛ рдХрд░реЗрдВред рдлрд┐рд░ рд╣рд░ 1.21.21.2 рд╕реЗ рд╡рд┐рднрд╛рдЬрд┐рдд рдХрд░реЗрдВред

╬ФVтЙИ0.061.2=0.05┬аpu\Delta V \approx \frac{0.06}{1.2} = 0.05\text{ pu}╬ФVтЙИ1.20.06тАЛ=0.05┬аpu

4

рдкрд░рд┐рдгрд╛рдореЛрдВ рдХрд╛ рд╡рд┐рд╢реНрд▓реЗрд╖рдг рдХрд░реЗрдВ

рдкрд░рд┐рдХрд▓рд┐рдд рдбреНрд░реЙрдк 0.05┬аpu0.05\text{ pu}0.05┬аpu рд╣реИред рджрд┐рдП рдЧрдП рд╡рд┐рдХрд▓реНрдкреЛрдВ рдкрд░ рд╡рд┐рдЪрд╛рд░ рдХрд░рддреЗ рд╣реБрдП, рд╡рд┐рдХрд▓реНрдк B (0.052┬аpu0.052\text{ pu}0.052┬аpu) рд╕рдмрд╕реЗ рдирд┐рдХрдЯрддрдо рд╕рдиреНрдирд┐рдХрдЯрди рд╣реИ, рдЬрд┐рд╕рдХрд╛ рдЙрдкрдпреЛрдЧ рдЖрдорддреМрд░ рдкрд░ рд╡рд┐рд╢рд┐рд╖реНрдЯ рд╕рд┐рд╕реНрдЯрдо рд╕реНрдерд┐рддрд┐рдпреЛрдВ рдХреЗ рд▓рд┐рдП рдЗрдВрдЬреАрдирд┐рдпрд░рд┐рдВрдЧ рд╕рдВрджрд░реНрднреЛрдВ рдореЗрдВ рдХрд┐рдпрд╛ рдЬрд╛рддрд╛ рд╣реИред

╬ФVтЙИ0.05┬аpu\Delta V \approx 0.05\text{ pu}╬ФVтЙИ0.05┬аpu

тЬЕ

B рд╕рд╣реА рд╣реИ рдХреНрдпреЛрдВрдХрд┐ рдЕрдиреБрдорд╛рдирд┐рдд рдЧрдгрдирд╛ 0.05┬аpu0.05\text{ pu}0.05┬аpu рдкреНрд░рд╛рдкреНрдд рд╣реЛрддреА рд╣реИ, рдЬреЛ рдХрд┐ рджрд┐рдП рдЧрдП рд╡рд┐рдХрд▓реНрдк 0.052┬аpu0.052\text{ pu}0.052┬аpu рдХреЗ рдЕрдиреБрд░реВрдк рд╣реИред

Core Concepts Used
Click any tag to open in AI Tutor
рд╡реЛрд▓реНрдЯреЗрдЬ рдбреНрд░реЙрдк рдкреНрд░рддрд┐ рдЗрдХрд╛рдИ (Per Unit) рд╕рд┐рд╕реНрдЯрдо рдкреНрд░рддрд┐рдХреНрд░рд┐рдпрд╛рд╢реАрд▓ рд╢рдХреНрддрд┐ рдкреНрд░рд╡рд╛рд╣
ЁЯТб EXAM TIP

рдкрд╛рд╡рд░ рд╕рд┐рд╕реНрдЯрдо рдореЗрдВ, рд╡реЛрд▓реНрдЯреЗрдЬ рдбреНрд░реЙрдк рдореБрдЦреНрдп рд░реВрдк рд╕реЗ рдкреНрд░рддрд┐рдШрд╛рдд рджреНрд╡рд╛рд░рд╛ рдирд┐рдпрдВрддреНрд░рд┐рдд рд╣реЛрддрд╛ рд╣реИ рдХреНрдпреЛрдВрдХрд┐ рдлреАрдбрд░ рдХрд╛ рдкреНрд░рддрд┐рд░реЛрдз рдЕрдХреНрд╕рд░ рдкреНрд░рддрд┐рдШрд╛рдд рд╕реЗ рдмрд╣реБрдд рдХрдо рд╣реЛрддрд╛ рд╣реИ (XтЙлRX \gg RXтЙлR)ред рдпрд╣ рд╕рдВрдмрдВрдз рд╡реЛрд▓реНрдЯреЗрдЬ рд╡рд┐рдирд┐рдпрдорди рдЕрдзреНрдпрдпрдиреЛрдВ рдХреЗ рд▓рд┐рдП рдорд╣рддреНрд╡рдкреВрд░реНрдг рд╣реИред

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext