Join 60,000+ competitive exam aspirants
If the handle of a three point starter goes to back to OFF position, it may be due to
overload
high filed circuit resistance
zero or very low voltage supply
all of these
all of these
A three-point starter uses a No-Volt Coil (NVC) to hold the starter handle in the 'ON' position against a spring force. If the NVC is de-energized due to supply failure, open field circuits, or overload tripping, the handle automatically returns to the 'OFF' position to protect the DC motor.
A three-point starter uses a No-Volt Coil (NVC) to hold the starter handle in the 'ON' position against a spring force. If the NVC is de-energized due to supply failure, open field circuits, or overload tripping, the handle automatically returns to the 'OFF' position to protect the DC motor.
FHтАЛтИЭ╬жтЛЕINVCтАЛ тАФ Holding force is proportional to the flux produced by the No-Volt Coil current.
INVCтАЛ=RfтАЛ+RstarterтАЛVтАЛ тАФ The current in the holding coil depends on supply voltage and field circuit resistance.
The NVC is connected in series with the motor shunt field circuit. If the field circuit resistance is too high, the current drops below the threshold required to maintain magnetic flux, causing the handle to release. Similarly, if the supply voltage is zero, the electromagnet loses its holding force, and the return spring pulls the handle back to 'OFF'.
The No-Volt Coil (NVC) acts as a safety device for under-voltage protection.
If the shunt field circuit is opened, IfтАЛ becomes zero, causing the NVC to release the handle.
Overload protection is provided by the Overload Release Coil (OLRC) which short-circuits the NVC terminals.
The return spring provides the mechanical tension to pull the handle to the OFF position.
Provides automatic protection against power failure
Ensures the motor always starts with the full starting resistance in the circuit
Cannot be used for wide-range speed control motors because changing field resistance affects NVC holding
Sensitive to supply voltage fluctuations
Used in DC Shunt and Compound motors
Standard startup mechanism in classic laboratory DC machines
In a three-point starter, the NVC and the shunt field are in series. This is why it is unsuitable for variable-speed DC motors.
If the supply voltage drops significantly, the electromagnet becomes weak, and the spring tension forces the handle back, preventing damage to the armature during a sudden return of full voltage.
D is correct тАФ The handle returns to the OFF position because the No-Volt Coil (NVC) fails to maintain the magnetic holding force due to power loss, excessive resistance in the field circuit, or short-circuiting by the overload coil.
Always remember that for speed control via field weakening, a Four-Point Starter is preferred over a Three-Point Starter to decouple the NVC from the field circuit fluctuations.