Join 60,000+ competitive exam aspirants
If the no-voltage release in a DC motor starter fails to operate on the failure of supply, on the resumption of supply the motor will
develop very low starting torque
start automatically without trouble
get damaged
not start automatically
get damaged
If the No-Volt Release (NVR) fails to release the starter handle upon supply interruption, the handle remains in the 'ON' position. Consequently, when the supply is restored, the full line voltage is applied directly across the stationary motor armature without the limiting resistance, leading to excessive current flow and physical damage.
If the No-Volt Release (NVR) fails to release the starter handle upon supply interruption, the handle remains in the 'ON' position. Consequently, when the supply is restored, the full line voltage is applied directly across the stationary motor armature without the limiting resistance, leading to excessive current flow and physical damage.
IaтАЛ=RaтАЛVтИТEbтАЛтАЛ тАФ Armature current equation where EbтАЛ=0 at start.
TaтАЛтИЭ╬жIaтАЛ тАФ Torque development in a DC motor.
The NVR coil is connected in series with the shunt field circuit. Under normal conditions, it acts as an electromagnet holding the starter arm against a spring. If the supply fails, the magnetic field collapses, and the spring pulls the arm to the 'OFF' position. Failure of this mechanism leaves the circuit complete, effectively connecting the low-resistance armature directly across the supply line when power returns, causing IaтАЛ=RaтАЛVтАЛтЙИтИЮ (theoretically) or a massive spike that destroys the winding insulation.
The No-Volt Release (NVR) acts as a safety feature for both No-Volt and Under-Voltage protection.
Without back-EMF (EbтАЛ=0), the motor behaves like a short circuit during the initial moments of full voltage application.
DC shunt motors require starting resistors to limit initial IaтАЛ to 1.5 to 2 times full load current.
Protects armature against excessive current during voltage dips or outages.
Ensures controlled start-up sequence.
Mechanical failure of the NVR spring or coil can lead to catastrophic motor failure.
Essential in 3-point and 4-point starters for DC motors.
The armature resistance (RaтАЛ) of a DC motor is typically very low, usually <1╬й.
Option A is incorrect because the torque would actually be extremely high due to high current, not low.
Option B is the desired operating mode but implies the NVR functioned correctly.
C is correct тАФ The motor will be subjected to full line voltage without starting resistance, causing an excessive surge current that damages the armature windings.
Always remember that in DC motors, current is limited by the starting resistance initially and by Back EMF (EbтАЛ) once the motor reaches speed. If EbтАЛ is zero and no resistance is present, the motor is effectively a dead short.