In a DC Motor 3 point starter is used to
provide protection against Low-Voltage
provide overload protection
limit the starting current to a safer value
all of the above
all of the above
A 3-point starter is essential for DC shunt and compound motors to safely initiate rotation by limiting starting current, providing under-voltage protection, and guarding against field failure. It integrates a starting resistor array, a No-Volt Coil (NVC), and an Overload Release (OLR) magnet within a single manual unit.
A 3-point starter is essential for DC shunt and compound motors to safely initiate rotation by limiting starting current, providing under-voltage protection, and guarding against field failure. It integrates a starting resistor array, a No-Volt Coil (NVC), and an Overload Release (OLR) magnet within a single manual unit.
IstartтАЛ=RaтАЛ+RextтАЛVтАЛ тАФ represents the initial current limiting mechanism
EbтАЛ=60AP╧ХZNтАЛ тАФ represents the back EMF generated as speed increases
During start-up, the handle is moved across contact studs to cut out the starting resistor, which limits the high initial current (IaтАЛ=RaтАЛVтИТEbтАЛтАЛ) as EbтАЛ is zero. The NVC holds the handle in the 'RUN' position when energized; if the supply voltage drops or fails, the NVC loses magnetism, and a spring returns the handle to 'OFF'. The OLR acts as a magnetic trip that short-circuits the NVC when current exceeds the rated limit, causing the starter to trip and protecting the motor.
The NVC is connected in series with the shunt field to provide protection against field failure (Field Failure Protection).
The starter handle must be moved gradually to ensure the starting current remains within safe limits (usually 1.5 to 2 times rated current).
The 3-point starter cannot be used for speed control as the NVC is connected to the shunt field circuit.
Protects the motor armature from high inrush currents during starting.
Automatically disconnects the motor upon power failure, preventing accidental restart.
Provides built-in protection against heavy mechanical overload.
Limited speed control capability compared to a 4-point starter.
The NVC current is dependent on field current; at high speeds (weakened field), the NVC might trip prematurely.
DC Shunt Motors
DC Compound Motors
In a 4-point starter, the NVC is connected independently of the shunt field, solving the issue of premature tripping during field weakening.
Option B is correct because the OLR coil is specifically designed to energize and trip the starter when the motor draws excessive current due to an overload.
D is correct тАФ The 3-point starter serves the triple purpose of limiting starting current, providing under-voltage protection via the NVC, and overload protection via the OLR coil.
Always remember that for speed control applications (field weakening), a 4-point starter is preferred over a 3-point starter because the holding coil circuit is independent of the field current.