Join 60,000+ competitive exam aspirants
If the starter is not used with large DC motor for starting, it will
damage the armature and commutator
draw a starting current many times its rated full load current
provide an excessive voltage drop in line
all of the above
all of the above
At the instant of starting, a DC motor is at standstill, meaning there is no back EMF (EbтАЛ=0). Since the armature resistance (RaтАЛ) is typically very low, the absence of back EMF causes the motor to draw an extremely high current, leading to severe damage to the commutator and windings.
At the instant of starting, a DC motor is at standstill, meaning there is no back EMF (EbтАЛ=0). Since the armature resistance (RaтАЛ) is typically very low, the absence of back EMF causes the motor to draw an extremely high current, leading to severe damage to the commutator and windings.
IaтАЛ=RaтАЛVтИТEbтАЛтАЛ тАФ Armature current equation for DC motor
EbтАЛ=60A╬жZNPтАЛ тАФ Back EMF equation
The starting current of a DC motor is governed by the relation IaтАЛ=RaтАЛVтИТEbтАЛтАЛ. At the moment of switching on (N=0), the back EMF EbтАЛ is zero, resulting in IaтАЛ=RaтАЛVтАЛ. Because RaтАЛ is negligible, this current is typically 10 to 20 times the rated full-load current, causing excessive heating and spark-related damage.
The primary function of a DC starter is to insert high resistance in series with the armature during the initial starting period.
As the motor gains speed, the back EMF builds up and the starter resistance is gradually cut out.
Large DC motors cannot self-limit starting current, necessitating external starting equipment.
Excessive current causes severe torque transients, which can damage mechanical couplings and gearboxes.
Limits starting current to a safe value
Prevents severe voltage dips in the power supply line
Protects armature windings from thermal insulation failure
Increased initial cost and complexity
Physical space requirement for the starter unit
Manual starters require operator expertise
Industrial DC motor drives
Rolling mills
Traction systems using DC series motors
DC shunt and compound motors use 3-point or 4-point starters.
Option B is correct because the low resistance of the armature circuit cannot limit current without back EMF.
Option C is correct because the surge of current causes a high voltage drop across the supply lines (VdropтАЛ=IaтАЛ├ЧRlineтАЛ), potentially affecting other connected equipment.
D is correct тАФ Using a starter prevents excessive starting current, which protects the motor windings, commutator, and the supply line from electrical and mechanical stress.
Always remember that for DC motors, EbтАЛ acts as a self-regulating mechanism only after the motor has attained significant speed.