Join 60,000+ competitive exam aspirants
In a closed cycle operation of gas turbines
Load variation is affected by controlling the absolute pressure and the mass flow of the circulating air
High efficiency is maintained over the complete range of operating loads
Maximum unit capacity is increased
All of above
Load variation is affected by controlling the absolute pressure and the mass flow of the circulating air
In a closed-cycle gas turbine system, the working fluid is recirculated through a heat exchanger, compressor, and turbine. Unlike an open cycle, the load variation is achieved by varying the density (mass flow) of the working fluid by changing the absolute pressure levels while keeping the cycle temperatures constant.
In a closed-cycle gas turbine system, the working fluid is recirculated through a heat exchanger, compressor, and turbine. Unlike an open cycle, the load variation is achieved by varying the density (mass flow) of the working fluid by changing the absolute pressure levels while keeping the cycle temperatures constant.
PmтАЛ=m╦ЩRT1тАЛln(P1тАЛP2тАЛтАЛ) тАФ Relation between mass flow and power output
╬╖thтАЛ=1тИТTmaxтАЛTminтАЛтАЛ тАФ Theoretical efficiency dependency
Load control is performed by the 'pressure level control' method. Since the temperature at the turbine inlet is maintained at the design value, the efficiency remains high even at part-load. Furthermore, because the working fluid can be a gas with superior thermodynamic properties (like Helium), the heat transfer coefficients are higher, allowing for more compact components and potentially higher unit capacities.
Closed cycles allow the use of working fluids other than air (e.g., Helium, Argon).
Pressure level control allows maintaining constant temperature ratios for high efficiency at part load.
External combustion in closed cycles prevents turbine blade fouling from fuel impurities.
Increased fluid density enables higher power density and smaller turbomachinery components.
High thermal efficiency at part-load conditions.
Compact size due to high working fluid pressure.
Working fluid purity prevents corrosion/erosion of blades.
Flexibility in heat source selection (e.g., nuclear, solar).
Requirement for a large, expensive external heat exchanger.
Complexity in pressure-tight sealing and system design.
Cooling water demand is significant for the pre-cooler.
Nuclear power plants (Gas-cooled reactors).
High-efficiency industrial cogeneration.
Solar thermal power generation systems.
Option A is correct because pressure level control is the primary mechanism for load regulation in closed cycles.
Option B is correct as the cycle efficiency depends mainly on the temperature ratio, which is kept constant by design.
Option C is correct because increased pressure allows for higher mass flow rates within the same machine volume.
D is correct тАФ All listed options are fundamental characteristics and advantages of closed-cycle gas turbine operation.
Remember that in open-cycle turbines, load is usually controlled by fuel flow rate (temperature control), whereas closed-cycle systems exclusively use pressure level control to optimize efficiency.