In a steam power plant cooling towers are used for
Cooling condensate outlet water
Cooling exhaust steam
Cooling feed water
All of above
Cooling condensate outlet water
In a steam power plant, the cooling tower is used to dissipate heat from the condenser cooling water into the atmosphere. The water leaving the condenser is warm and is circulated through the cooling tower to be cooled before being returned to the condenser for re-use.
In a steam power plant, the cooling tower is used to dissipate heat from the condenser cooling water into the atmosphere. The water leaving the condenser is warm and is circulated through the cooling tower to be cooled before being returned to the condenser for re-use.
Q=m╦ЩCpтАЛ╬ФT тАФ Heat transfer equation for cooling water
QevapтАЛ=m╦ЩevapтАЛLvтАЛ тАФ Heat removed via latent heat of vaporization
The cooling tower utilizes the principle of evaporative cooling. Warm water from the condenser is sprayed into the tower where it comes in contact with ambient air; a portion of the water evaporates, absorbing latent heat and significantly lowering the temperature of the remaining liquid water.
Cooling towers are essential for closed-loop cooling systems in thermal power plants.
They reduce the requirement for fresh water makeup by recycling the condenser coolant.
The process relies on direct contact between warm water and air to facilitate evaporation.
Performance is highly dependent on ambient wet-bulb temperature.
Significant reduction in makeup water consumption.
Eliminates the need for large quantities of constant water discharge into natural water bodies.
Environmentally friendly compared to once-through cooling systems.
High initial cost for construction.
Loss of water through evaporation and drift.
Maintenance required to prevent scaling and biological growth.
Thermal power plants (Coal, Gas, Nuclear).
HVAC systems for large industrial complexes.
Oil refineries and chemical processing plants.
Option B is incorrect because steam is condensed inside the condenser using cooling water, not by the tower directly.
Option C is incorrect because cooling towers specifically handle condenser circulation water, not the high-pressure feed water pumped to the boiler.
A is correct тАФ Cooling towers are utilized to lower the temperature of the water used to condense steam in the condenser, allowing it to be recycled efficiently.
Always distinguish between the 'cooling water' (which cools the condenser) and the 'feed water' (which goes into the boiler); cooling towers only manage the cooling water circuit.