Join 60,000+ competitive exam aspirants
In steam turbines, the reheat factor
Increases with the increase in number of stages
Reduces with increase in number of stages
Remains the same irrespective of number of stages
None of above
Increases with the increase in number of stages
The reheat factor (RF) in a steam turbine is the ratio of the cumulative heat drop across individual stages to the isentropic heat drop across the entire turbine expansion. As the number of stages increases, the reheat factor increases because the inefficiency of one stage (manifested as reheat) becomes available for extraction in subsequent stages.
The reheat factor (RF) in a steam turbine is the ratio of the cumulative heat drop across individual stages to the isentropic heat drop across the entire turbine expansion. As the number of stages increases, the reheat factor increases because the inefficiency of one stage (manifested as reheat) becomes available for extraction in subsequent stages.
RF=╬ФhtotalтАЛтИСi=1nтАЛ╬ФhstageтАЛтАЛ тАФ Definition of Reheat Factor
╬╖internalтАЛ=RF╬╖stageтАЛтАЛ тАФ Relation between internal and stage efficiency
In an actual turbine, the expansion process is not isentropic due to internal losses. These losses cause an increase in the enthalpy of the steam compared to an ideal isentropic expansion. Since the pressure ratio across later stages is lower due to this reheat effect, the cumulative sum of the individual stage enthalpy drops exceeds the total isentropic drop across the turbine. This ratio is defined as RF = (sum of stage heat drops) / (total isentropic heat drop), and it is always greater than unity.
Reheat factor is always greater than 1.0 for multi-stage turbines.
It accounts for the 'reheating' effect of stage internal friction losses.
For a single-stage turbine, the reheat factor is equal to 1.
Higher stage efficiency results in a reheat factor closer to unity.
Accounts for the energy recovery from internal losses.
Provides a more accurate assessment of turbine thermal performance.
Complexity in calculation for high-pressure stages.
Dependent on the specific design and number of expansion stages.
Performance analysis of multi-stage steam turbines.
Design optimization of power plant turbines.
The reheat factor typically ranges between 1.02 and 1.06 in large power turbines.
Option B is incorrect because reheat is cumulative; more stages capture more 'lost' energy as heat, thus increasing the factor.
A is correct тАФ The reheat factor increases with the number of stages as the internal losses of one stage act as heat input for subsequent stages, increasing the cumulative energy availability.
Always remember that reheat factor is a consequence of entropy increase within the turbine stages; in a perfectly reversible (isentropic) expansion, the reheat factor would be exactly 1.