The value of rehear factor for a multistage steam turbine lies in the range of
005 to 1.03
01 to 1.06
02 to 1.1
10 to 1.2
01 to 1.06
The reheat factor is a consequence of the thermodynamic irreversibility in multistage turbines. Because the losses in one stage (represented as heat) are partially recovered in subsequent stages, the cumulative enthalpy drop exceeds the total isentropic enthalpy drop across the entire turbine, resulting in a reheat factor typically between 1.01 and 1.06.
The reheat factor is a consequence of the thermodynamic irreversibility in multistage turbines. Because the losses in one stage (represented as heat) are partially recovered in subsequent stages, the cumulative enthalpy drop exceeds the total isentropic enthalpy drop across the entire turbine, resulting in a reheat factor typically between 1.01 and 1.06.
RF=╬ФhtotalтАЛтИС╬ФhstageтАЛтАЛ тАФ Definition of Reheat Factor
WactualтАЛ=RF├ЧWisentropicтАЛ тАФ Work output relation
In an ideal turbine, expansion is isentropic. In a real multistage turbine, the fluid friction and turbulence in an upstream stage increase the enthalpy of the steam. This 'lost' energy (reheat) is available for expansion in the downstream stages, which effectively increases the total work output compared to the sum of individual stage works. The reheat factor is the ratio of the sum of individual stage isentropic enthalpy drops to the total isentropic enthalpy drop between the initial and final pressures.
Reheat factor is always greater than unity.
It accounts for the 'reheating' of steam due to internal friction losses.
The factor depends on the number of stages and stage efficiency.
Higher stage efficiency typically leads to a lower reheat factor.
Increases the overall thermal efficiency of the power plant cycle.
Enables accurate estimation of actual turbine work output.
Calculation requires detailed stage-by-stage analysis.
Does not improve the cycle efficiency as much as external reheating.
Steam turbine performance analysis.
Design of multi-stage thermal power plant turbines.
The range 1.01 to 1.06 is standard for large utility-scale steam turbines.
If the turbine has only one stage, the reheat factor is 1.0.
B is correct тАФ The reheat factor for multistage steam turbines typically falls within the range of 1.01 to 1.06.
Always remember that reheat factor is a consequence of entropy increase; it is an 'internal' reheat effect, distinct from the 'external' reheating used in the Rankine cycle to improve quality at the turbine exhaust.