Poor power factor
reduces load handling capability of electrical system
results in more power losses
results in more voltage drop
all of the above
reduces load handling capability of electrical system
A poor power factor (low cos╧Х) implies that a significant portion of the current supplied is reactive current rather than active power. This increases the total current drawn from the source for a given real power requirement, leading to various inefficiencies in the power system.
A poor power factor (low cos╧Х) implies that a significant portion of the current supplied is reactive current rather than active power. This increases the total current drawn from the source for a given real power requirement, leading to various inefficiencies in the power system.
P=VIcos╧Х тАФ Real Power
S=VI тАФ Apparent Power
I=Vcos╧ХPтАЛ тАФ Current draw at constant load
The active power is given by P=VIcos╧Х. To maintain constant P at a low cos╧Х, the line current I=Vcos╧ХPтАЛ must increase. This increased current leads to higher I2R losses, larger voltage drops across the transmission line impedance Z=R+jX (specifically VdropтАЛтЙИI(Rcos╧Х+Xsin╧Х)), and forces generators and transformers to operate at higher apparent power (S=VI) ratings, effectively reducing their useful load-carrying capacity.
Low power factor increases the required cross-sectional area of conductors for a specific load.
It leads to inefficient utilization of capital equipment like transformers and generators.
Poor power factor causes higher voltage regulation issues, leading to unstable voltage at the consumer end.
Improving power factor reduces electricity bills in industrial tariff structures.
Enhanced power factor improves equipment longevity by reducing thermal stress.
Requires installation of capacitor banks, which adds cost.
Over-correction can lead to leading power factor, which may cause unwanted voltage rises.
Industrial motor drives
Transmission and distribution networks
Most industrial loads are inductive (motors, transformers), leading to a lagging power factor.
Option A is correct because the generator/transformer capacity (VA) is limited; higher current for the same watts leaves less room for real work.
Option B is correct because losses are I2R, so higher I exponentially increases copper losses.
Option C is correct because the line impedance causes a larger drop as I increases.
D is correct тАФ Poor power factor increases current flow, leading to increased copper losses, higher voltage drops, and reduced effective power capacity of electrical infrastructure.
Remember that power factor correction using shunt capacitors provides reactive power locally, which prevents the need to transmit this current through the entire grid, minimizing losses.