Join 60,000+ competitive exam aspirants
Select the correct statement while designing a singly reinforced beam in the limit state method.
A designer may have multiple solutions.
Under reinforced beams have brittle failure.
Under reinforced beams have minimum cross section area.
Only over reinforced beams are designed.
A designer may have multiple solutions.
In the design of a singly reinforced beam, a designer has multiple variables such as the width (b), effective depth (d), grade of concrete (fckтАЛ), and grade of steel (fyтАЛ) to work with. For a given factored moment (MuтАЛ), there are infinitely many combinations of width and depth that satisfy the equilibrium conditions, allowing the designer flexibility in selection.
IS 456:2000 Cl. 39.1
In the design of a singly reinforced beam, a designer has multiple variables such as the width (b), effective depth (d), grade of concrete (fckтАЛ), and grade of steel (fyтАЛ) to work with. For a given factored moment (MuтАЛ), there are infinitely many combinations of width and depth that satisfy the equilibrium conditions, allowing the designer flexibility in selection.
MuтАЛ=0.87fyтАЛAstтАЛd(1тИТbdfckтАЛAstтАЛfyтАЛтАЛ) тАФ Ultimate moment of resistance for a singly reinforced beam
dxuтАЛтАЛ=0.36fckтАЛbd0.87fyтАЛAstтАЛтАЛ тАФ Neutral axis depth ratio
The design process involves satisfying the limit state of collapse in flexure, ensuring MuтАЛтЙдMu,limтАЛ. Because the cross-sectional dimensions are often constrained by architectural requirements or deflection criteria (l/d ratio), the designer selects b and d first, then determines the required area of steel (AstтАЛ) to resist the applied moment.
The depth of the beam is often limited by deflection control criteria.
Economic design usually involves selecting AstтАЛ such that the beam is under-reinforced.
Over-reinforced beams are prohibited by code to prevent sudden brittle failure.
Design flexibility allows balancing concrete and steel costs.
Optimization for architectural constraints.
Trial and error is often required for an optimal cross-section.
Changes in depth significantly impact the dead load of the structure.
Residential building slab/beam systems.
Industrial floor beams.
Option B is wrong because under-reinforced beams provide ductile failure, allowing warning before collapse.
Option C is wrong because balanced sections have the minimum area for concrete, while under-reinforced beams require more concrete depth compared to balanced sections.
Option D is wrong because over-reinforced design is explicitly avoided in IS 456 to ensure ductility.
A is correct тАФ A designer may have multiple solutions.
Always remember that in IS 456 design, we prefer under-reinforced sections (xuтАЛ<xu,maxтАЛ) to ensure the steel yields before the concrete crushes, providing a ductile failure mode.