Join 60,000+ competitive exam aspirants
Single phase AC distributor supplies two single phase loads as shown in the figure. The voltage drop from A to C is
5 V
31.5 V
30 V
20 V
30 V
The voltage drop from point A to C in an AC distributor is calculated by summing the individual voltage drops across each section using the load currents and section impedances. Since the total current flows through the segment AB and only the load current flows through segment BC, the total drop is the sum of drops in these segments calculated using the impedance voltage drop formula VdropтАЛ=I├ЧZ.
The voltage drop from point A to C in an AC distributor is calculated by summing the individual voltage drops across each section using the load currents and section impedances. Since the total current flows through the segment AB and only the load current flows through segment BC, the total drop is the sum of drops in these segments calculated using the impedance voltage drop formula VdropтАЛ=I├ЧZ.
Vdrop(AC)тАЛ=IABтАЛZABтАЛ+IBCтАЛZBCтАЛ тАФ Total voltage drop calculation
VdropтАЛ=I(Rcos╧Х+Xsin╧Х) тАФ Voltage drop in terms of power factor
In a radial distributor, the current at any segment is the sum of all currents downstream of that segment. If segment AB carries I1тАЛ+I2тАЛ and segment BC carries I2тАЛ, the voltage drop is given by VdropтАЛ=IABтАЛZABтАЛ+IBCтАЛZBCтАЛ. By applying the phase values of the currents and impedances, the total complex voltage drop is determined.
Voltage drop in a distributor depends on the load current and the impedance of the line segments.
For AC systems, impedance Z=R+jX must be considered, meaning the drop involves vector addition.
Load currents are additive in the direction away from the source.
Simple calculation method for radial systems.
Direct determination of voltage stability at load points.
Sensitive to variations in load power factor.
Inefficient for very long feeders due to high voltage regulation requirements.
Residential distribution feeders.
Secondary low-voltage distribution systems.
The calculation assumes the distributor is fed from one end.
The 30V result is obtained by performing the vector summation of drops across the segments AB and BC based on the provided load parameters.
C is correct тАФ The total voltage drop from A to C is determined by summing the individual vector voltage drops across segments AB and BC.
Always convert load currents into polar or rectangular form before summing or multiplying by impedance, as AC voltage drops are phasor quantities.