The armature resistance control method is also called as __________?
constant torque control
constant power control
constant voltage control
constant current control
constant torque control
The armature resistance control method is known as constant torque control because it maintains the magnetic flux (╬ж) at its rated value while varying the armature voltage drop. Since electromagnetic torque (TeтАЛтИЭ╬жIaтАЛ) remains proportional only to the armature current (IaтАЛ) when flux is constant, the motor can deliver constant rated torque across its speed range.
The armature resistance control method is known as constant torque control because it maintains the magnetic flux (╬ж) at its rated value while varying the armature voltage drop. Since electromagnetic torque (TeтАЛтИЭ╬жIaтАЛ) remains proportional only to the armature current (IaтАЛ) when flux is constant, the motor can deliver constant rated torque across its speed range.
TeтАЛ=KaтАЛ╬жIaтАЛ тАФ Electromagnetic torque equation
N=K╧ХтАЛ╬жVтИТIaтАЛ(RaтАЛ+RextтАЛ)тАЛ тАФ Speed equation for DC motor
In this method, an external variable resistor is inserted in series with the armature circuit. By increasing the resistance, the voltage drop across it increases, reducing the back EMF (EbтАЛ=VтИТIaтАЛRaтАЛ) and consequently reducing the motor speed. Because the field flux remains constant at its maximum rated value, the motor is capable of maintaining its full-load torque throughout the speed reduction process.
Used for speeds below the rated speed.
The method is inefficient due to large power dissipation in the external series resistor (Ia2тАЛRextтАЛ).
Torque remains constant as long as the flux is maintained at rated value.
Commonly applied to DC series and shunt motors.
Simple and inexpensive setup
Provides speed control below base speed
Significant power loss in the external resistor
Poor speed regulation at high resistance values
Not suitable for speeds above rated speed
Printing presses
Cranes and hoists where intermittent low-speed operation is required
| Feature | Armature Resistance Control | Field Flux Control |
|---|---|---|
Control Range | Below base speed | Above base speed |
Constant Power Control is typically associated with Field Flux Control (Field Weakening), where speed is increased above rated speed while power remains relatively constant.
Option B (Constant power control) is incorrect as it describes field weakening, not armature resistance control.
A is correct тАФ The armature resistance control method is termed constant torque control because the motor retains its full-load torque capacity across the controlled speed range by keeping the flux constant.
Always remember: Armature Resistance Control = Below base speed (Constant Torque); Field Flux Control = Above base speed (Constant Power).