The height of chimney, in a steam power stations, is governed by
The draught to be produced
The quantity of flue gases being produced
Pollution control
All of above
The draught to be produced
The primary function of a chimney in a steam power station is to produce natural draught to facilitate the flow of air and flue gases through the furnace. The magnitude of this draught is directly proportional to the chimney height, which is necessary to overcome the pressure drops across the furnace, fuel bed, economizer, and air preheater.
The primary function of a chimney in a steam power station is to produce natural draught to facilitate the flow of air and flue gases through the furnace. The magnitude of this draught is directly proportional to the chimney height, which is necessary to overcome the pressure drops across the furnace, fuel bed, economizer, and air preheater.
h=H(TaтАЛ353тАЛтИТTgтАЛ493тАЛ) тАФ Draught head in meters of hot gas column, where H is height, TaтАЛ is ambient temp, and TgтАЛ is gas temp.
Natural draught is created by the difference in density between the hot flue gases inside the chimney and the cold atmospheric air outside. Because the hot gases are less dense than the ambient air, a pressure difference is created at the base of the chimney. This pressure difference acts as a pump, drawing fresh air into the furnace for combustion and pushing exhaust gases out. The height H is the fundamental parameter that determines the static pressure head generated by this density gradient.
The draught produced is directly proportional to the chimney height.
Higher chimneys are required for larger boiler capacities to overcome total friction losses.
Natural draught is an eco-friendly way to induce flow without mechanical fans.
Pollution dispersion also depends on chimney height, but the primary technical constraint for boiler operation is draught production.
No external power required for operation
Low maintenance cost
Long operational life
Efficiency drops as ambient temperature rises
Limited pressure head compared to forced draught fans
Small to medium scale thermal power plants
Furnaces requiring steady gas exhaust
While pollution control (Option C) is a significant factor in deciding chimney height due to local emission regulations (dispersion models), the engineering governing principle for the boiler's combustion system remains the production of necessary draught.
Option B (quantity of flue gases) affects the diameter of the chimney rather than the height.
A is correct тАФ The chimney height is fundamentally determined by the requirement to generate sufficient natural draught to maintain constant combustion and flue gas flow.
Always distinguish between the 'operational requirement' (draught) and the 'environmental requirement' (dispersion) when discussing chimney height.