Join 60,000+ competitive exam aspirants
The number of discs in a string of insulator for 400 kV AC overhead transmission line lies in the range of
32 to 33
22 to 23
15 to 16
9 to 10
22 to 23
For a 400 kV transmission line, the string of suspension insulators typically consists of 22 to 23 standard discs. Each disc is generally rated for 11 kV to 15 kV, and the total number of discs is determined by considering the phase-to-earth voltage, safety factors, and potential overvoltage transients.
For a 400 kV transmission line, the string of suspension insulators typically consists of 22 to 23 standard discs. Each disc is generally rated for 11 kV to 15 kV, and the total number of discs is determined by considering the phase-to-earth voltage, safety factors, and potential overvoltage transients.
Vph=3VL — Calculation of phase voltage from line voltage
η=n×Vline−unitVtotal — String efficiency formula
The number of insulators is determined by the system voltage Vph=3VL. For 400 kV, Vph≈231 kV. Since the voltage distribution across a string is non-uniform due to shunt capacitance, we use a string efficiency factor. The total number of discs is N≈Voltage rating per disc×String EfficiencyVph×Factor of Safety.
String efficiency is always less than 100% due to unequal potential distribution across discs.
The disc nearest to the conductor experiences the highest potential stress.
Standard cap-and-pin type porcelain or glass insulators are used for 400 kV lines.
Grading rings are often employed to equalize the potential distribution along the string.
Modular design allows for easy replacement of damaged discs.
Provides high mechanical strength and electrical insulation for HV lines.
Susceptible to flashover due to pollution accumulation on disc surfaces.
Potential distribution across the string is non-linear.
Extra High Voltage (EHV) AC transmission lines.
Suspension towers in power transmission networks.
400 kV lines commonly use 22 or 23 discs of 255/280 mm diameter.
Higher number of discs is required if the system is located in highly polluted environments (higher leakage distance).
Options A, C, and D provide ranges that do not correspond to standard empirical design practices for 400 kV systems.
B is correct — 22 to 23 discs are required to withstand the 400 kV system voltage while accounting for string efficiency and safety margins.
Always remember that for a given voltage, increasing the number of insulators improves string efficiency but increases tower height and cost; balance is key in transmission tower design.