Join 60,000+ competitive exam aspirants
What is the relation of the current with the starting torque in the starter concept?
the starter should restrict current to prevent low starting torque
the starter should restrict current to produce high starting torque
the starter should send current to prevent low starting torque
the starter should send current to produce high starting torque
the starter should send current to produce high starting torque
In DC motors, the starter acts as a current-limiting device during the initial start-up phase where back EMF is zero. By limiting the excessive rush of current while maintaining necessary magnetic flux, it ensures the motor develops sufficient starting torque to overcome inertia without damaging the armature windings.
In DC motors, the starter acts as a current-limiting device during the initial start-up phase where back EMF is zero. By limiting the excessive rush of current while maintaining necessary magnetic flux, it ensures the motor develops sufficient starting torque to overcome inertia without damaging the armature windings.
IaтАЛ=RaтАЛ+RextтАЛVтИТEbтАЛтАЛ тАФ Armature current equation with starter resistance
TaтАЛтИЭ╬жIaтАЛ тАФ Electromagnetic torque relation in DC motors
At standstill, the back EMF (EbтАЛ=0). According to the equation IaтАЛ=RaтАЛVтИТEbтАЛтАЛ, the armature current is very high if RaтАЛ is low. The starter adds external resistance in series with the armature to restrict this current to safe levels while allowing sufficient current flow to produce high electromagnetic starting torque, defined as TaтАЛтИЭ╬жIaтАЛ.
DC motors require high starting torque to overcome static friction and load inertia.
The back EMF is zero at standstill, necessitating an external resistor to prevent an infinite surge of current.
As the motor gains speed, EbтАЛ increases, allowing the starter resistance to be gradually cut out.
Prevents overheating and burning of armature conductors.
Ensures smooth acceleration of the motor.
Energy is dissipated as heat in the starting resistors.
Adds complexity and cost to the motor control assembly.
Shunt and Compound DC motor starting.
Industrial machinery requiring high break-away torque.
The starter does not restrict current at the cost of torque; rather, it manages the current to ensure it remains at a level capable of driving the required starting torque safely.
Option A is incorrect because the objective of the starter is to facilitate a controlled start, not to inhibit the generation of the necessary starting torque.
D is correct тАФ the starter manages armature current to ensure the motor can safely generate the high torque required for rotation from a standstill.
Always remember that in DC motors, IaтАЛ is directly proportional to TaтАЛ; therefore, starters are designed to maintain the highest safe IaтАЛ to achieve maximum possible starting torque.