Join 60,000+ competitive exam aspirants
What is the work of the starter with respect to the mechanical stress?
to allow large mechanical stress
to restrict large mechanical stress
to allow small mechanical stress
to restrict small mechanical stress
to restrict large mechanical stress
A DC motor starter is used to restrict the large starting current, which in turn limits the mechanical stress (torque surge) exerted on the armature and shaft during the initial starting phase. By inserting external resistance in series with the armature, the starter prevents the massive current inrush that occurs because back EMF is zero at standstill.
A DC motor starter is used to restrict the large starting current, which in turn limits the mechanical stress (torque surge) exerted on the armature and shaft during the initial starting phase. By inserting external resistance in series with the armature, the starter prevents the massive current inrush that occurs because back EMF is zero at standstill.
IstartтАЛ=RaтАЛ+RextтАЛVтАЛ тАФ Starter current limitation formula
╧Д=kтЛЕ╬жтЛЕIaтАЛ тАФ Torque expression showing dependence on IaтАЛ
At standstill, the back EMF (EbтАЛ) of a DC motor is zero. Since the armature resistance (RaтАЛ) is very low, the starting current IaтАЛ=RaтАЛVтИТEbтАЛтАЛ would be dangerously high. This excessive current creates a massive electromagnetic torque surge that causes high mechanical stress on the armature windings, commutator, and mechanical coupling. The starter adds external resistance (RextтАЛ) initially to limit IaтАЛ=RaтАЛ+RextтАЛVтАЛ, gradually cutting out this resistance as the motor gains speed.
At the instant of starting, back EMF is zero.
The armature resistance of a DC machine is extremely low.
High current results in severe mechanical shock to the shaft due to high starting torque.
The starter effectively increases total resistance to keep IaтАЛ within 1.5 to 2 times the rated current.
Prevents damage to the commutator and brushes
Protects the armature windings from insulation failure
Prevents voltage dips in the supply line
Adds weight and cost to the machine assembly
Power loss occurs in the external resistance during starting
Starting of DC Shunt Motors
Starting of DC Compound Motors
Mechanical stress refers to the shear force acting on the armature conductors and the torsion experienced by the shaft when the motor suddenly attempts to reach high torque at zero speed.
Option A is incorrect because allowing large stress would lead to mechanical fatigue or failure.
B is correct тАФ The starter is designed to restrict large mechanical stress by limiting the initial inrush of armature current.
Always remember that in DC motors, high current IaтАЛ at starting does not only damage the winding via I2R heating but also causes significant mechanical wear due to high starting torque ╧ДstartтАЛ.