Which of the following machine is not considered in the calculation of the resistance steps?
DC Series motor starter
DC Shunt motor starter
Phase IM (Cage Rotor)
Phase IM (Slip Ring)
Phase IM (Cage Rotor)
Resistance starters are used to limit the high starting current of motors by adding external resistance in the circuit. A Squirrel Cage Induction Motor (SCIM) has a permanently short-circuited rotor, which makes it impossible to add external resistance, unlike DC machines or Slip-Ring Induction Motors.
Resistance starters are used to limit the high starting current of motors by adding external resistance in the circuit. A Squirrel Cage Induction Motor (SCIM) has a permanently short-circuited rotor, which makes it impossible to add external resistance, unlike DC machines or Slip-Ring Induction Motors.
RtotalтАЛ=RarmatureтАЛ+RextтАЛ тАФ Total resistance in DC motor starting circuit
TstтАЛтИЭR22тАЛ+(sX2тАЛ)2sE22тАЛR2тАЛтАЛ тАФ Torque equation for Induction Motor
In DC shunt/series motors, external resistance is added in series with the armature to limit IstтАЛ=RaтАЛ+RextтАЛVтИТEbтАЛтАЛ. In Slip-Ring induction motors, external resistance is added to the rotor circuit to increase starting torque and limit current. In Cage Induction Motors, the rotor bars are end-ringed and not accessible for external connection, hence resistance steps cannot be inserted.
Resistance starters are specifically designed for machines where rotor or armature circuits are accessible.
Squirrel cage motors use Star-Delta or Soft starters instead of resistance steps.
DC motors use a multi-point starter (3-point or 4-point) to cut out resistance as speed increases.
Slip-ring IMs use a rotor rheostat to improve starting torque and reduce current.
Reduces starting inrush current
Provides controlled acceleration for high inertia loads
Energy loss in the form of heat during starting
Increased size and cost of the control equipment
DC Shunt/Series motor speed/start control
Wound rotor induction motor drives
Cage Induction motors are often started using DOL, Star-Delta, or Autotransformer starters.
The resistance in a slip-ring motor is only present during the starting phase and is cut out as the motor reaches operating speed.
C is correct тАФ Cage induction motors feature a permanently short-circuited rotor structure, making it physically impossible to introduce external resistance steps into the rotor circuit.
Always remember that resistance starting is only applicable to motors where you can reach the electrical nodes of the rotor or armature circuit; cage induction motors are 'closed' systems.