Which of the following is the reason for the high starting current in DC Motor?
Back EMF is ZERO in starting
Rotor EMF is ZERO in Starting
No magnetic locking between Stator and rotor field
pulsating (not rotating) magnetic field
Back EMF is ZERO in starting
At the moment of starting, a DC motor's armature is stationary, meaning the rotor speed (N) is zero. Since Back EMF (EbтАЛтИЭ╬жN) is directly proportional to speed, the Back EMF generated in the armature circuit at starting is zero.
At the moment of starting, a DC motor's armature is stationary, meaning the rotor speed (N) is zero. Since Back EMF (EbтАЛтИЭ╬жN) is directly proportional to speed, the Back EMF generated in the armature circuit at starting is zero.
EbтАЛ=60A╬жZNPтАЛ тАФ Back EMF equation of a DC Motor
IaтАЛ=RaтАЛVтИТEbтАЛтАЛ тАФ Armature current equation
Ia,startтАЛ=RaтАЛVтАЛ тАФ Starting armature current (since EbтАЛ=0)
The armature current of a DC motor is governed by the voltage equation IaтАЛ=RaтАЛVтИТEbтАЛтАЛ. Because armature resistance (RaтАЛ) is kept extremely low (typically less than 1┬а╬й) to minimize I2R copper losses during normal operation, the absence of Back EMF (EbтАЛ=0┬аV) at N=0┬аrpm causes a heavy surge of starting current (Ia,startтАЛ=RaтАЛVтАЛ) that can be 5 to 7 times the rated full-load current.
At N=0┬аrpm (standstill), EbтАЛ=0┬аV, causing high starting current Ia,startтАЛ=V/RaтАЛ.
High starting current can damage commutator brushes, melt armature winding insulation, and produce severe line voltage drops.
A starter (e.g., 3-point or 4-point starter) adds external resistance in series with the armature circuit strictly during starting to limit IaтАЛ.
Option B refers to induction motor concepts (rotor induced EMF at standstill is maximum, not zero).
Option C is incorrect because magnetic locking/coupling occurs between field poles and armature poles to produce electromagnetic torque.
Option D describes single-phase induction motor action, whereas DC motors produce a steady unidirectional magnetic field.
A is correct тАФ At the moment of starting, the rotor speed is zero (N=0), which makes the back EMF (EbтАЛ=0), causing a huge armature current surge through the low-resistance armature.
In AC 3-phase induction motors, the high starting current is due to low standstill rotor impedance (high slip s=1), whereas in DC motors, it is strictly due to zero back EMF (EbтАЛ=0).