Which of the following statement is/are not correct for automatic DC motor starters.
Start button, Main and Auxilary contact is always NO
Stop Button & Overload Relay contact is always NC
The overload coil is always connected to the control circuit
The overload coil is always connected to the power circuit
The overload coil is always connected to the control circuit
In automatic DC motor starters (such as Direct-On-Line or automatic resistance starters using contactors), the overload coil (OLC) carries the full heavy armature current or main line current. Therefore, the overload sensing coil is connected directly in series with the power circuit, while its normally closed (NC) auxiliary contacts are connected in the control circuit to trip the contactor coil upon an overload.
In automatic DC motor starters (such as Direct-On-Line or automatic resistance starters using contactors), the overload coil (OLC) carries the full heavy armature current or main line current. Therefore, the overload sensing coil is connected directly in series with the power circuit, while its normally closed (NC) auxiliary contacts are connected in the control circuit to trip the contactor coil upon an overload.
IaтАЛ=RaтАЛVтИТEbтАЛтАЛ тАФ Armature current during starting and operation
FOLCтАЛтИЭIaтАЛ" тАФ Magnetic force generated by the overload coil proportional to armature current ]
keyPoints
:
The overload sensing coil carries high load current and is connected in series with the motor armature in the power circuit.The auxiliary contacts of the Overload Relay (OLR) are normally closed (NC) and connected in series with the contactor operating coil in the control circuit.The Start push button is normally open (NO) and connected in parallel with the main contactor's auxiliary NO contact (seal-in/holding contact).The Stop push button is normally closed (NC) and connected in series with the control circuit to interrupt power during emergency stop.
advantages
:
Protects the motor windings from overheating due to sustained overcurrent.Provides automatic remote control and push-button operation via low-current control wiring.
disadvantages
:
Requires proper current calibration of the overload coil to prevent nuisance tripping.Adds complexity with separate power and control circuit wiring.
applications
:
Automatic starter panels for DC shunt and series motors.Industrial automation systems utilizing contactors and relay-based starter controls.
comparisonTable
:
additionalInfo
:
Option A is correct: Start buttons and auxiliary holding contacts are normally open (NO).Option B is correct: Stop buttons and OLR safety contacts are normally closed (NC) for fail-safe protection.Option D is correct: Overload coil is physically located in the power circuit to directly sense motor line current.Option C is NOT correct (and thus the correct choice for this question) because connecting the low-impedance overload coil in the control circuit would fail to measure armature current and cause a short circuit.
answer
:
C is correct тАФ The overload coil is connected in the power circuit in series with the motor armature, whereas only its auxiliary contacts are connected to the control circuit.
correctedOptions
:
Start button, Main and Auxilary contact is always NOStop Button & Overload Relay contact is always NCThe overload coil is always connected to the control circuitThe overload coil is always connected to the power circuit
coreConcepts
:
Automatic DC Motor StartersPower vs Control CircuitsOverload Relay (OLR) Mechanism
crossTopicTip
:
Remember: High current sensing devices (e.g., OLC, series field) are always in the Power Circuit, whereas control elements (Pushbuttons, Relay auxiliary contacts, Contactor coils) belong to the Control Circuit.
When an overload occurs, the high current flowing through the overload coil in the power circuit generates a strong magnetic force (or sufficient thermal heat in thermal OLRs). This force operates a mechanical linkage that opens the Overload Relay (OLR) contacts situated in the control circuit. Opening these NC contacts breaks the energizing current to the main contactor coil, causing the main power contacts to open and safely disconnect the motor from the supply.