As per Euler’s theory, for which of the following end conditions is the longest effective length of a column obtained?
When one end of the column is fixed and the other end is hinged
When both the ends of the column are hinged
When one end of the column is fixed and the other end is free
When both the ends of the column are fixed
When one end of the column is fixed and the other end is free
Euler’s theory defines the effective length (Le) based on the end constraints of a column, which dictates the buckling load. The longest effective length occurs when the column is most susceptible to buckling, which is the case for a column fixed at one end and free at the other.
IS 800:2007, Table 11
Euler’s theory defines the effective length (Le) based on the end constraints of a column, which dictates the buckling load. The longest effective length occurs when the column is most susceptible to buckling, which is the case for a column fixed at one end and free at the other.
Pe=Le2π2EI — Euler's buckling load formula
Le=2L — Effective length for fixed-free condition
The effective length (Le) is defined as the length of an equivalent column with pinned ends that would have the same buckling load as the actual column. For a cantilever column (fixed-free), the curvature of the buckled shape is restricted to a quarter-wave, resulting in an effective length of twice the actual length (Le=2L). This increases the slenderness ratio significantly compared to other end conditions.
Fixed-Free: Le=2L
Hinged-Hinged: Le=L
Fixed-Hinged: Le=L/2≈0.707L
Fixed-Fixed: Le=L/2
Predicts stability in compression members
Provides a theoretical basis for calculating safe load capacity
Only applicable for long, slender columns where failure is due to buckling rather than crushing
Assumes ideal end conditions which are difficult to achieve in practice
Design of steel structural columns
Analysis of long slender machine components
The buckling load is inversely proportional to the square of the effective length; hence, the fixed-free condition carries the lowest load capacity.
Option B (Le=L) is the benchmark, while Option D (Le=0.5L) provides the highest load capacity.
C is correct — The fixed-free end condition results in an effective length of 2L, which is the maximum among all standard end configurations.
Always remember the mnemonic '2-1-0.7-0.5' for the multipliers of L in the order of Fixed-Free, Pinned-Pinned, Fixed-Pinned, and Fixed-Fixed to avoid calculation errors in GATE/ESE exams.