Join 60,000+ competitive exam aspirants
Which of the following methods make use of infra-red lamp In the determination of water content of soils ?
Alcohol method
Calcium carbide method
Torsional balance method
Pycnometer method
Torsional balance method
The Torsional balance method, also known as the Infra-red moisture balance method, uses an infra-red lamp for rapid drying of a soil sample. It integrates a torsion balance for accurate weighing and an infra-red heat source to evaporate moisture quickly.
IS 2720 (Part 2): 1973
The Torsional balance method, also known as the Infra-red moisture balance method, uses an infra-red lamp for rapid drying of a soil sample. It integrates a torsion balance for accurate weighing and an infra-red heat source to evaporate moisture quickly.
Water┬аContent(w)=W2тАЛW1тАЛтИТW2тАЛтАЛ├Ч100% тАФ where W1тАЛ is initial weight and W2тАЛ is dry weight of soil
The soil sample is placed on a pan attached to a torsion balance. An infra-red lamp is positioned above the pan to provide consistent thermal radiation. As the moisture evaporates, the weight of the sample decreases, which is tracked by the torsion balance until a constant reading is achieved, indicating the dry state.
Useful for quick field determination of water content.
The infra-red lamp ensures uniform heating and rapid evaporation.
Not suitable for soils with high organic content which might char.
Faster than the conventional oven-drying method.
Compact and portable equipment setup.
Potential for error if organic matter decomposes due to excessive heat.
Requires careful calibration to prevent sample burning.
Quick site moisture control in earthwork construction.
Laboratory testing for rapid moisture measurement.
Alcohol method uses methylated spirit and is used for quick field estimation but is less accurate.
Calcium carbide method is based on gas pressure measurement (C2тАЛH2тАЛ gas).
Pycnometer method is primarily used for finding the specific gravity of soil solids.
C is correct тАФ The Torsional balance method utilizes an infra-red lamp for the rapid determination of soil water content by maintaining a balance between moisture loss and weight measurement.
Always remember that the Oven-drying method is the standard laboratory method, whereas methods like Calcium Carbide and Torsional Balance are rapid field/lab methods used for quick estimation.