If тАЩHтАЩ is the overall height of a retaining wall retaining a surcharge, the width of the base slab usually provided is _______.
0.1 H
0.2 H
0.3 H
0.6 H
0.6 H
For a cantilever retaining wall, the base width is determined by the stability requirements against overturning and sliding. When a surcharge load is present, the lateral earth pressure increases significantly, necessitating a wider base slab to ensure safety, typically ranging between 0.5H to 0.7H, with 0.6H being the standard design recommendation for preliminary sizing.
IS 456:2000 (Plain and Reinforced Concrete)
For a cantilever retaining wall, the base width is determined by the stability requirements against overturning and sliding. When a surcharge load is present, the lateral earth pressure increases significantly, necessitating a wider base slab to ensure safety, typically ranging between 0.5H to 0.7H, with 0.6H being the standard design recommendation for preliminary sizing.
BтЙИ0.6H тАФ Empirical estimation for base width
PaтАЛ=KaтАЛтЛЕ╬│тЛЕHтЛЕ(H+2hsтАЛ)тЛЕ21тАЛ тАФ Total lateral earth pressure force with surcharge
MoтАЛ=PaтАЛтЛЕ3HтАЛ тАФ Overturning moment
The base slab provides a lever arm for the self-weight of the concrete and the weight of the backfill soil resting on the heel slab to counteract the overturning moment caused by lateral earth pressure. The inclusion of a surcharge increases the active earth pressure (PaтАЛ=KaтАЛ╬│H(H+2hsтАЛ)/2), requiring a larger resisting moment; thus, a base width of 0.6H is provided to shift the resultant force within the middle third of the base to avoid tensile stresses and ensure stability.
Base width is primarily a function of wall height (H) and soil properties.
Surcharge loads increase the active pressure, demanding a wider base for stability.
Preliminary sizing usually adopts 0.5H to 0.7H depending on the angle of internal friction.
The middle-third rule is critical to prevent tension at the base interface.
Increases the factor of safety against overturning.
Provides a larger base area to reduce bearing pressure on the soil.
Enhances sliding resistance through soil weight on the heel.
Increased excavation volume required for a wider base.
Higher consumption of concrete and reinforcement steel.
Increased footprint on the land, potentially problematic in congested areas.
Bridge abutments subject to traffic surcharge.
Retaining walls for highway embankments.
Basement walls supporting external ground loads.
For walls without surcharge, the thumb rule often used is 0.4H to 0.5H.
Option A, B, and C are typically insufficient to provide the necessary stability against overturning when a significant surcharge is applied behind the wall.
D is correct тАФ The standard design rule of thumb for the width of a base slab for a retaining wall with surcharge is 0.6H to ensure stability against overturning and sliding.
In competitive exams, always remember that 'surcharge' increases the effective height of the wall; if you see the word 'surcharge', expect a higher coefficient for the base width calculation.