Join 60,000+ competitive exam aspirants
When the T-beam is continuous, the assumed overall depth of the beam of heavy loads is taken as ________.
101тАЛ \text{ to }$$\frac{1}{12} ┬аof┬аspan
121тАЛ \text{ to }$$\frac{1}{15} ┬аof┬аspan
151тАЛ \text{ to }$$\frac{1}{20} ┬аof┬аspan
201тАЛ \text{ to }$$\frac{1}{25} ┬аof┬аspan
101тАЛ \text{ to }$$\frac{1}{12} ┬аof┬аspan
For continuous T-beams subjected to heavy loads, the preliminary design assumes an overall depth ranging from 101тАЛ to 121тАЛ of the effective span. This ratio ensures sufficient stiffness and prevents excessive deflection, which is critical under heavy structural loads.
General structural engineering practice based on IS 456 guidelines for preliminary sizing.
For continuous T-beams subjected to heavy loads, the preliminary design assumes an overall depth ranging from 101тАЛ to 121тАЛ of the effective span. This ratio ensures sufficient stiffness and prevents excessive deflection, which is critical under heavy structural loads.
D=span├Чk, where k is between 101тАЛ and 121тАЛ
╬┤maxтАЛ=384EI5wL4тАЛтЙдallowable┬аlimits
The depth-to-span ratio acts as a thumb rule for initial sizing of structural members to control deflection and ensure that the beam behaves monolithically with the slab. Heavy loading increases the demand on the section modulus, requiring a deeper beam compared to simply supported or lightly loaded conditions.
Preliminary sizing is essential to initiate the structural analysis process.
Continuous beams are generally more efficient than simply supported beams, but heavy loads necessitate higher stiffness-to-span ratios.
Excessive depth increases self-weight, while insufficient depth leads to serviceability failure (deflection/cracking).
Controls long-term deflection effectively.
Ensures economic reinforcement ratios by providing adequate depth for lever arm.
Increased dead load due to deeper sections.
Higher floor-to-ceiling height consumption.
Preliminary design phase of multi-storey RCC frames.
Industrial buildings with heavy machinery loads.
For simply supported beams, the ratio is often assumed higher (e.g., 81тАЛ to 101тАЛ).
Option B (121тАЛ to 151тАЛ) is often used for lighter or standard loading conditions.
A is correct тАФ The assumed overall depth for continuous T-beams under heavy loads is typically taken as 101тАЛ to 121тАЛ of the span.
Remember that continuous beams are more rigid than simply supported ones, which allows for smaller depth-to-span ratios, but this is balanced by the heavy load demand.